Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. beximus

    Two drives but only one is used

    Thank's 605, i have removed all devices from pool and problem is solved.
  2. beximus

    Two drives but only one is used

    I am using other pools Week 1 Week 2.... Month Year and both devices are assigned to a pool (s)
  3. beximus

    Two drives but only one is used

    Legato Networker ver 6.2 Windows Server Parallelism = 8 23 clients Parallelism = 4 Groups Parallelism = 8 Target sessions = 4 I have storage node with 2 drives Tape0 and Tape1 I run only one group at the same time With this settings there is only one...
  4. beximus

    Backup Exec 8.6 & Hp Ultrium 1/8 Autoloader LTO-a

    Hi, I try to install HP Ultrium autoloader 1/8 Lto-2 and Backup Exec 8.6 see it as a stand alone device. I have the latest drivers from veritas. It is a multi lun autoloader and the scsi card configuration is ok. Any idea?
  5. beximus

    Upgrade from 6.2 => 7.2 on Windows adv Server

    We're planning on migrating from networker 6.2 to version 7.2 On windows 2000 AVD server. Does anyone knows the process of upgrading to networker 7.2 from release version 6.2. I'm worried about licensing. thank you in advance.
  6. beximus

    Legato Networker vs OpenView Storage Data Protector 5.5

    Please let me know your opinion on the best data protection solution. Legato Or Open View Storage data protection.
  7. beximus

    Browse and Retention policies!

    When the browse and retention policies are expired, but data is still available on tapes, how can i restore data???
  8. beximus

    Splitting up a 500GB Netware Volume

    saveset example \members\a* if i want to recover saveset a* i don't get output, I can't browse \members\a* but i can browse (example) \members\abc \members\abcd \members\asdfg \members\az...... and then recover...
  9. beximus

    Splitting up a 500GB Netware Volume

    Legato networker 6.2 Windows I have a next situation: one first level directory with more then 600 second level directories (user accounts) I have tried with wildcards and they are alowed, but i can't restore that saveset anymore. browse metode work's
  10. beximus

    1 save set with more than 1TB

    Hello all, Can anybody help me in the following issue: Problem environment: Networker 6.2, Windows directory \test\ => 1TB directory test have more than 150 first level subfolders . How can I divide \test directory (in more than one save set)??? I can't change the folder structure. How can...
  11. beximus

    data error (cyclic redundancy check)

    I m using Legato networker 6.2 (windows), LTO tapes , 2 Tapes Tape0 Tape1 only on tape0 i get the folowing error message. Tape0 moving: fsr 10054: Data error (cyclic redundancy check.) if i disable the tape0, then i get no error messages. everything works fine with tape1. does this tape0 need...