Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. jocas9

    IP Node Config issue on CS1000 Release 6

    Hi, check if you have your tps and related applications running on your SS. Go to UCM, login as admin and go to applications then check for all nortel applications and if tps is down start that application. Best Regards, JCS
  2. jocas9

    Can't put CDr push to work

    No need to answer this question, after I installed the 083-CUMULATIVE-PATCH everything works fine. Thanks the same Jose Carlos
  3. jocas9

    Can't put CDr push to work

    Hi, I have a BCM 50 and I have configured to use the Push option. I use Guild FTP to act as a server of ftp and I configure the BCM with the ip address of the server - its mine laptop at this moment - and when I press push to test the bcm, all the times says "Unable to get FTP connection -...
  4. jocas9

    Does anyone uses CDR live on BCM50

    Hi, I have a BCM50 and I want to retrieve cdr, but live. As soon you finish the call you see the ticket. I tried to use the sample program that came with the bcm50 but all the time - I use win xp professional- the program give me "Run Time error 53 File not found: CdrClient.dll - but the file is...
  5. jocas9

    Read DataNumber from Connection Directory

    After a while, serching on the books and sample scripts I put this working. This is the final script: String client String phonenumber commandmode on transmit "at^M" waitfor "K^M^J" transmit "at+ms=v34^M" waitfor "K^M^J" transmit "at^M" client = $DIALENTRY set dialentry...
  6. jocas9

    Read DataNumber from Connection Directory

    As you can see on my script I start with comandmode on.Any more tips ???? Best Regards, Jose Carlos
  7. jocas9

    Read DataNumber from Connection Directory

    I miss one point, I tried to use dial Data number and he dial the entry but the configuration I made, before, on the modem is disregarded (transmit "ath\n1s37=5^M"). I hope this is clear. Best Regards, Jose Carlos
  8. jocas9

    Read DataNumber from Connection Directory

    Hello all, I'm trying to read to a variable the DataNumber from the connection directory. I wrote this script: ;Recorded script. Editing may be required. proc main String numero commandmode on transmit "at^M" waitfor "K^M^J" transmit "ath\n1s37=5^M" waitfor "K^M^J"...
  9. jocas9

    Reset M3905 password

    Hi, I have a customer that forgot the password to access the directory key ( to see who has calling, the calls made and so on).Is any way to reset this password. Best Regards, Jose

Part and Inventory Search

Back