Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. mundus

    Call_list fail after upgrade to Mx-One 7.3 sp1

    Hi I thing you need to assign virtual extension licens to the generic: extension –c –d x --virtual yes
  2. mundus

    how to know correct version system

    Hi LZY2035101/1/R1A LZY20351 BC 9 01 Standard application and accorfing to the Identity it seems to be in version CNI 81
  3. mundus

    how to know correct version system

    It's BC 9 with Application system - Standard
  4. mundus

    Fault code without alarm class

    Hi, ADD INFO 1 contains the relevant fault code. Here it's 782 which is an external source alarm, so at the ALU input 1-x-xx-x there must be an entry which is short-circuited.
  5. mundus

    roddi command for a numbering range?

    use PNR - it's simpel and it's working !
  6. mundus

    What extensions assigned to LIM

    SUDIP:LIM=x; print out all data for directory numbers stated in parameter LIM - but it gives much print!
  7. mundus

    ip networking

    please post route and dest from both jeddah and dammam: RODAP:ROU= ; ROCAP:ROU= ; RODDP:DEST= ; RODDP:DEST= ,IPOPT=YES; ROEDP:ROU= ,TRU=ALL; RIANP:ROU= ; RINIP:LIM=ALL;
  8. mundus

    Paging

    The type of signaling used: ESPA or ? And please specified the signaling protocol: dialtone, meet-me, speech etc.
  9. mundus

    B Number conversion on internal dialing

    sorry for my late respons ! a short/brief description: 1. assign a common oacc with nansi:numtyp oc/od and opcoi NB! you can only have one coacc in the exchange, in your case 44444. 2. assign some "dummy" oacc (just for routing purchase) with nansi:numtyp oc/od and opcts:corg=x,oacc="first...
  10. mundus

    B Number conversion on internal dialing

    just a suggestion: make 44444 as a coacc and then use cust and empty corg with rernum to the difference b numbers.
  11. mundus

    IP networking

    Hi' Call-back, the MX-one is using Generic protocol and the MD use the Proprietary protocol (RODDI ADC d17) according to your data - here you shall use the same protocol at both. PNR, here it could be the SRT in dest 6999 that is wrong - the SRT in RODDI for PNR calls refer to the ENTRY from PNR...
  12. mundus

    Operator auto extend to CTI group.

    opiss:dir= ,extend= ;
  13. mundus

    Operator auto extend to CTI group.

    Hi´ have you try fast extending - EXTEND=E or F ?
  14. mundus

    free seating

    Hi, you can do this by DISA with: *75* regional authorization code * free-seat number # - new dialtone - #11* free-seat number # Assign a regional authorization code: AUCOI:DIR=free-seat number,AUTH= ,CILCOD= ,CAT= ; To allow DISA with regional authorization code: ASPAC:PARNUM=184,PARVAL=1...
  15. mundus

    Incoming call

    d1, d2, ... d10 when d5 = 0 blocked for traffic from public exchange (DID traffic). If you also want to block transferred public line, then look at ASPAP 67 and ADC d7 (ananlog extension).
  16. mundus

    Incoming call

    Hi' "How to block incoming call in a analogic extension?" if incoming call is from a DID, then you can use the SERV d5 (for analog extension) to block.
  17. mundus

    Nortel and Ericsson MD110 QSIG connectivity

    to be sure, could you post: RODAP, ROCAP and relevant RODDP and ASPAP:PARNUM=223;
  18. mundus

    Nortel and Ericsson MD110 QSIG connectivity

    Try adc d5=0 in RODDI, Nortell don't supported Aastra UUIx. The same with vari d2 and d3 =00 - no UUIx. adc d25 should be set to 1 - Call back/call compl. as Generic. adc d13 = 1 sending TCM to a Nortell ?? Another important value is AS PARNUM 223 which should be 7.
  19. mundus

    IP TRUNKING FROM 2 SITE BC12sp8

    Hi in site 1 you have assigned a local route id - ROU98, but when calling from site 2 there is no remote route id ! Try in site 1: RIANC:ROU=98,LROUID=""; or assign RROUID="ROU98" in site 2.
  20. mundus

    HUNT GROUP

    SEL d2=0 internal calls towards the group shall NOT be queued !

Part and Inventory Search

Back
Top