OK.... am trying to see how to change the setings from frac to full...but the csu is configured for 24 channels. Is there somewhere I am missing on where to change these settings?
CSU is an Adtran CSU Ace
It is a full T1--upgraded from a frac
the former frac was configured on s0/1 and is shutdown
sh controller s0/0
Interface Serial0/0
Hardware is PowerQUICC MPC860
DTE V.35 TX and RX clocks detected.
idb at 0x80870E68, driver data structure at 0x80876218
SCC Registers:
General...
Whoops....sorry about that.
Module type is T1/fractional
Hardware revision is 0.88, Software revision is 1.07,
Image checksum is 0x8510A6B6, Protocol revision is 0.1
Transmitter is sending remote alarm.
Receiver has loss of signal, loss of frame,
Framing is ESF, Line Code is B8ZS...
Yes...repeatedly...(grrrrrr)....they say that the line tests clean....
Telco is where I started as well....as most of the time that I've seen issues like this they have almost always been circuit related.
I have 2 routers connected via T1. (3600 <-> 2600) Both have serial T1 cards and external CSU/DSU's. The issue is that I am getting tons of input and crc errors on both ends of this connection.
Results of sh int on the 3600
10807488 input errors, 10217351 CRC, 0 frame, 1448 overrun, 0...