Hi
I don't wont converting a-number to b-number
I would like convert A-number incoming in the MD for transit, and dosn't work (in another exhange this work, but I supose this is the patch that you say)
Then I proved to convert b-number incoming from that route to get the call working in a route...
Any one knows if there is any problem with nutri in transit in BC10 paq PRE-C?
There is some of them working ok (cnvtyp=0, cnvtyp=1), but trying doing some more, any works cnvtyp=0 and neither cnvtyp=2.
I´m not sure if there is some problem in transit between private and public TON or signalling...
I've just proved what you said but it still fail
Do you know if there is any other variable that I must modify? path or anyother?
I can't uninstall the KB840987, and in the client I can't uninstall the sp4.
Any ide before formating?
Thanks
corch
I have the same problem, and it is bc12sp2, but I have serious problems with synchronization.
I´ve proved putting the TLU79 in 1-0-00 and in 1-0-30, and the result is INTERNAL SYNC ERROR. Any idea?
Thanks.
Hi
Perhaps you can help me
¿Which is the difference between IP in RIANP and IP in RODDI? Any of them can be used as a mask of getting connection to more than one board?
If I want to use the same ELU32 for several routes, can I define several groups on it, or I must use only RODDI to choose where...
Thanks
I always try keeping them in the same revision, but my customer has GJUG3 and I haven´t got anyone if any of them go in a fault, so I wanted be sure before.
(Sorry by my english)
By
Hi
Anyone know if it´s possible putting Event Manager with NIU and without AAU?
If it is, how can I get mib traps from the alarms?, Is there any application that translate them?
Thanks
Hi
In an analoge route with incoming and outgoing traffic, in case of a lot of traffic trunks are taken from both sides at a time. Is it possible changing anything in the route to avoiding this?
thanks
Do you confirm and passivate patchs in MD110 without known if the revision of the program is the correct, or if is associated with another patch or program?
There isn´t a path in that specific adress, but there is one before it, but I´m not sure if it would be good passivating a path if I dont know what it does.
It´s S73577A
Anyway, I´m not sure the problem were in elp6, because after restarting, it first lost some signals from cgp to cgp and after...
Hi
I have several lost signals from elp6 to elp6 like this
TIME DATE ERROR CODE
15:26:15 29APR04 H'1F
FAULTY ACCESS
LIMIT EXCEEDED
LOGICAL PROGRAM ERROR ADDRESS = 0200CEC4
LOGICAL ERROR ADDRESS = 0181231D
PHYSICAL ERROR ADDRESS =...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.