  1. miller7

    Phaser 340 - 04.005.44:8700 what does this mean?

    From the service manual: 04,005.44 PC_DEV_FAULT_DM_CAM_ERROR: Failure positioning drum maintenance cam during a drum maintenance cycle; check drum maintenance cam solenoid, clutch, home sensor, and related hardware.