Hello,
after one day more, the results of the error in the serial line are:
ROGT1
ROGT1#show int
Ethernet0/0 is up, line protocol is up
Hardware is AmdP2, address is 000a.4105.19a1 (bia 000a.4105.19a1)
Internet address is 10.10.10.6/24
MTU 1500 bytes, BW 10000 Kbit, DLY 1000 usec...
We had the ROGT1 to full duplex mode, and the switch when it was connected to half duplex mode. After change the router to half duplex mode, there is no more CRC errors in ethernet0, but yes collisions and deferred.
After reset the statistic counters, we have the following error in the serial...
Routerman, thanks for your reply.
But I'm continuing lost in it. Please, I need more help!
About NO collisions on the E0/0 output for ROGT1 is very strange for me, because
we have a software implemented that tests if the lan way has a problem, this software uses pings in order to check the...
Thanks a lot Burke for your reply.
I will try to answer to your questions:
The routers in the main site are:
ROGT1 for one ethernet, and ROGT2 for another ethernet.
The router in the remote site are:
ROSV1 for connecting to the ROGT1, and ROSV2 for connecting to the ROGT2
1) About the...
More info about the routers. I send all the statistics:
ROGT1
Ethernet0/0 is up, line protocol is up
Hardware is AmdP2, address is 000a.4105.19a1 (bia 000a.4105.19a1)
Internet address is 10.10.10.6/24
MTU 1500 bytes, BW 10000 Kbit, DLY 1000 usec,
reliability 250/255, txload 3/255...
I've a WAN joined by 4 routers. Two in one local site, and two in another remote site.
In each site, there are two lans, so, each router is for the communication of each lan.
We use ethernet port of the router for connect the lan of each site, and then, we use the serial port of the router for...