Hi
NO , the machien came with a SCSI adaptor and a SCSI Hard Disk.
My question is this.. Is it impossible to set these machines to boot from an IDE Drive.
The drive is recognised in the bios , but cannot get it to be the boot device
Thanks for any help
Pete
I have a Dell Poweredge 800 server. The machine came with an adpatec scsi controller and hard disk.
Having some problems with scsi disk, so want to switch back to a normal ide disk.
I have removed the scsi controller , and installed a seagate 40gb ide disk as a master on the ide cable. I have...
I am looking to upgrade our 3.12 server to a 4.2 server.
With 3.12 i cannot use the nptwin95.exe command to load
a remote printer . This means i am having to have win 95 and win98 machines just to load up the remote printers.
My question is this . In Netware 4.2 is it possible to have remote...
Hi
I have looked for help with this , but had no luck.
When i connect a win xp pro machine to a netware 3.12 machine , i seem to have 1 extra connection 'not logged in'.
If i connect with numerous xp machines , i only still have the 1 'not logged in' connection which doesnt seem to be tied to...
Hi
Many thanks for your replies , however none of the mentioned threads are in relation to what i am having problems with.
Let me try and explain ..
The Foxpro routine runs fine , absolutely fine , NOT slow .
However the processor is showing at between 90 and 100% capacity.
If you try and...
I am running a couple of applications using both Foxpro 2.5
and 2.6. The applications are on a Netware 3.12 Server and i am running them from a XP Pro machine.
The applications run fine , except that CP usage goes to 98% whenever they are run. Hence , opening any other applications (Word /...
Just to follow up on this.
I eventually found out that if you call the runtime
routine from a pif file , then everything works great.
You CAN run runtime 2.5 under XP but you gotta use a pif to call it.
This is similar to the Windows For Workgroups idea from about 7 years ago.
Rob
Thanks again
Our application is not an exe file . For various reasons
we run from the compiled spr , fxp etc...
Thus i need to run foxr first and then call the fxp routine to start the application.
Bit antiquated i know , but there are reasons.
And using the 2.6 version of foxr still...
Rob
I already tried that also. I have a folder /foxrt where all
the files are. I made it so that it only contained the following
Driver2.plb
Foxr.exe
Genpd.app
Foxdx260.esl
When you run the foxr you get the error message :
"Cannot locate the desired version of Foxpro"
Isnt there...
Thanks rob , i got the file.
However , what do i do with this?
The runtime version i am running (2.5)has 6 files
Driver2.plb
Foxr.exe
Genpd.app
Foxd250a.esl
Foxdx25a.esl
Foxd250a.eso
Excuse my ignorance , but how do i utilise the Foxdx260.esl
file. I tried removing the foxdx250.esl and...
Rob
I do not have the Professional edition .
Is it possible for a link to the runtime version.
Or is it still possible to buy a runtime version
Regards
Pete
Thanks for yor reply.
What is the difference between the two runtime versions.
And why would it work ok with runtime under windows 95/98 , but then stop when running under xp.
Does the runtime 2.5 version not recognise the statment in
config.nt?
Regards
Pete
Does anybody know of an answer for this.
I have a foxpro 2.x application which works fine when run using Foxprox ver2.6 , but when run using 2.5 Runtime,
always get an error 'Too Many Files Open'
I have got a files=200 line in my config.nt file , but that
does not seem to help.
The runtime...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.