Who's handing out the ID10T awards? I added a 0x16 station module to support the 4 new ports of the NAM. I cross-connected the first 5 ports to a 10-port RJ11 Bix field and used ports 1-4 for the NAM and #5 for my test phone... All good. NEVER checked ports 1-4 with the test phone...all dead...
Thx! I did not XFTEST... Wanted the safety of plugging the Flash back in without issue (thankfully).
To confirm... leave KSU system on, unplug FLASH do XFTEST, remove F codes, plug in NAM and boot... Cross fingers and go.
If successful, I may need to pull the NAM for a day to program and...
I have a customer who decided to "upgrade" from Flash 4 to NAM due to need for more capacity.
System is 8x24DS (NT5B20FC) upgraded to DR5 (30MUH05)
RTP 30GBG03, with trunk module and 2 station modules.
NAM is NT5B75AC-93 Rel 05 4-port, 8-Channel copper version 4.1.05
The NAM initializes and...