We use microlite backup edge, they support rev drives on sco, I have only tried ide and scsi rev drives on 5.0.6 they are working perfectly, you might download the 90 day demo and give it a try. Or just drop their support an email to see if they think it will work. It is a solid product we...
I have not used a zebranet print server in quite a while but I do remember having to use a specific remote queue name for the printer. I would go in and manually change the rp= flag in /etc/printcap to "text" or "pcl" based on what you are sending to it, I would guess "text" in your case. You...
Hi,
I have a customer running 5.0.5m. They log into the system to run our app which is being exec'd at the end of the users .profile. When they log out of our application at the end of the day the system is still showing them logged in. Our app does not allow concurrent logins so when they try...
I usally just make the same entries that motoslide suggested, I would add to his suggestion, if you are using hostresorder local bind and don't have dns setup locally that you might want to make entries for your lan nodes in /etc/hosts otherwise you may have major delays with ftp and telnet...
I have one customer having an ongoing problem with users not being logged out when they are done with our application. Their profiles are set to exec our app so they have no shell access, exiting the program should drop their telnet session, which it is doing. If you execute who it still shows...
Well we have pretty much just given up on this, we have tried every suggestion here as well as other things we have thought of and nothing seems to work other than a reboot of the machine. After the reboot all the modems work perfectly for a while then start failing again. I would like to try...
Yes this has been done to every modem, I have restrapped and replaced all cables and db25->rj45 adapters. The modems were working all morning, I can pinpoint when they all stopped working again to when someone tried to access a particular system, the modem on the other end picked up started to...
I have used cu directly many times, I would usally start and with the same commands you have suggested , the problem is neither of them work in this situation, after ~. the modem disconnects but the session hangs. The modem is unresponsive to any other commands.
Trying to cu directly into the modems is now giving me just about the same results, tty locks up and I need to go to another and kill the process, the dialers should not even be called when doing a direct connect....was going to try to direct connect and try the init string one command at a...
We are still having problems with certain modems, timing out dialing into some systems, but not others, the modems I replaced were replaced with the same models we have used for years:
multitech: MT1932ZDX, MT2834ZDX
we have always used the usrobotics dialers with these modems and have never had...
I took your suggestion and changed all of the devices and then updated Systems, still the problem persists. It was a good suggestion, but the devices file has been the same for 5 years with no problems. We have all of our communication vendors coming in tomorrow to troubleshoot the lines on...
I have directly connected to all seven modems and restrapped them with the same command set we have been using for years. They all tested ok (we use atl5l6l7 to see the setups) The example ACU I posted was just the first ACU there are six more blocks for each of the remaining modems on...
Hi,
I have tried hayes2400 with the same results, also I looked at gettydefs as well but bening that I have tried moving all of the modems to another server running 5.0.6 with a totally different gettydefs file with the same result. Just for good measure I restored gettydefs from a year ago...
Hello,
We use cu heavily to support customers and have been for years about two weeks ago we started having major problems with our call scripts that use cu to dialout, very flaky some customers worked other didn't. We called the phone company to check the lines, they said they were clean. We...
Thanks for the great tip removed the dir and the install went further now I get this error:
\) Patch "SCO:Unix OSS646B.506.SCO.Unix" can not be applied to "SCO:Unix
5.0.5Eb". Component is in an invalid state.
I am going to try a thorough system check and see if...
Please if anyone has any other input it would be greatly appreciated, I am this close to doing a remote re-install with the customer over the phone, this would truly suck and take 8+ hours including 3rd party software....any ideas????
-aseidas
I have had a hard time with this as well on linksys print servers. I have been able to get it to work by using the linkys bi-admin utility to set auto convert LF->CR cannot remember exactly where it is and I don't have the software installed anymore this was a couple of years ago but it worked...
I have been trying to install OSS646b from media images ona customer's system and having strange problems. I have placed all 1 VOL files in a dir /tmp/oss646b then run custom choosing their system and putting in ->media images->then entering the path to the file /tmp/oss646b. I get thos...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.