Hi all !
I have the same problem !
I have an G700 with S8300 with CM 2.1.1 and VAL Manager 2.0.8. Any idea? Have you solved the problem already?
thanks !
Hi all,
i have many problem to get the following running:
I have a ISDN Fax-Server card connected to an Definity TN556 BRI Card, administered as data-Modul WCBRI. So far all works fine. But i want to get 10-15 extension numbers, which should be all redirected to the data-modul extension (for...
Hi!
Time - sync is working fine. Also the mwi-indicators are working fine. Turning on and off the led is all working OK. But if you look into the activity-log at audix, you can see, that audix turns off the mwi every 3-4 min.
Button-assignments are all OK
Hi,
i have checked all setting, but everything looks like OK.
But Audix 4.0 does only have 12 ports. So i have only 12 ports programmend, port 12 turns on/off the MWI.
Any idea?
rigobert
Hi there,
i don't know if this is normal: Our Definity Audix 4.0 in DS-mode updates the MWI (LWC) approx. every 3 min. when an message is left. You can see this when pressing the button MSG-RETR. Is this an error?
best regards,
Rigobert
Hi,
it is a faxcard from ferrari-electronic.
Now it works!! i have replaced the TN556 Circuit Pack, it seems, that the BRI Line card was defective.
Thanks a lot,
rigobert
The copy-paste doesn't work, perhaps my DAS Release 1.0.17 German is too old. I do not get an pop-up menu when i click right in the emulator window :-(
Hi !
thanks for your answers. At the moment i try to make a tracing file from our Fax-Server Software (that i was told by the tech-support from the fax-server manufactorer).
Perhaps a little silly question: How do i paste the station form in here? I am not able to copy it in DSA.
best regards
Hi Dimas,
what do you mean by "Station form into the studio"?
I have tried to use data-module instead of station -> same problem. I can set up a connection with 2 channel (channel-bundling) to ONE calling-number, but not 2 connections to different numbers.
Hi !
I am also interested in this. How can you configure a wcbri port that you are able to place 2 calls simultaneous on this line? I have connect a ISDN FAX-SERVER card to the Definity, but the card is only using 1 B-Channel instead of two.
best regards
Hi,
thank for your answers, but i have solve the problem myself! It was not a problem with the SPID, but with the INTERFACE on the first screen at BRI-TRUNK FORM. In Germany you shoul set it to USER / ETSI / TEI = 0 / N / Y / Y / Y. The second page should not be changed from default. So it...
Hi,
i have some problems how to set up an ISDN BRI Line correctly. I should be a normal wcbri station (connected on a TN556 Board) with etsi standard. Normally an ISDN line has 2 B-Channels, but i am currectly only able to use 1 Channel at a time. I have a Fax-Server ISDN card connected to it...
As far as i know, you must set up a signalling group only for PRI / DS1-connection. On a BRI-Board i am not able to set up such a group. What do you mean by SPID's ?
Hi Dimas,
the same error occures, when i make call through ars. The route pattern is set up correctly and call-type is bothunr.
Perhaps i have only a little error in the configuration of the BRI TRUNK BOARD or the Trunk Group. Does anybody know the correct settings for Germany (EURO-ISDN BRI)...
Thank!
i checked COS / COR but there is not wrong entry. I have also tried to set up an TAC (*87) in the trunk-group-form and activated Dial-Access. When i dial *87 i get dial tone, but i am not able to make an outside call.
At "List trace station 100" i get the following:
...
active...
Hi all,
i hope anyone can help me. I have trouble to get an ISDN BRi Trunk TN2185B running in Germany. I have configured the BRI-TRUNK-BOARD und set up a trunk-group 1. When i enter "STATUS TRUNK-GROUP 1" then the service-state "IN_SERVICE/IDLE" appears, bu i am not able to...