Again, I appreciate the suggestions but still experiencing the same problem.
Changed the CO Type to ATT and removed 25 from the Rls ID, no change in call behavior.
Also tried changing route to VCE, trunk is stills set for DID. With this change I no longer get a half ring on the analog...
It wouldn't allow me to remove the CLOP. Received a Swh
SIDE
CNEG
RLS
RCAP xclop
SCH0531
RCAP ****
OVL000
>err sch0531
>
SCH0531
Unable to match input with stored mnemonics. The RCAP prompt in overlay
16 has been answered NDS when QSUr QSIG GF are not accessible or with
an inappropriate...
I do have an IDC table associated with this route, but this extension is not configured. Here is the dch programming.
ADAN DCH 4
CTYP MSDL
CARD 01
PORT 1
DES primcot
USR PRI
DCHL 1
OTBF 32
PARM RS422 DTE
DRAT 64KC
CLOK EXT
IFC NI2
ISDN_MCNT 300
CLID OPT0...
Forgot to also mention, the inbound call will ring the phone for just a split second, partial ring and then the call drops. I an call the extension internally without issue.
Yes, the carrier is sending digits for ext. 1991.
Here is the RDB and a trunk that is built.
REQ: prt
TYPE: rdb
CUST 0
ROUT
ACOD
TYPE RDB
CUST 00
DMOD 1
ROUT 2
DES LOCAL COT
TKTP DID
NPID_TBL_NUM 0
SAT NO
RCLS EXT
DTRK YES
BRIP NO
DGTP PRI
ISDN YES
MODE PRA
IFC NI2
CBCR NO...
I'm attempting to setup a PRI with a new carrier. Outbound calls work just fine but inbound calls will connect for just a split second and then drop. Below are the d-channel messages I have captured from the call. Trunks are configured as DID and PRI is set for National. Hoping someone might...