Thank you Wanebo, I appreciate your answer. Unfortunately for me, I don't have injectors.
If you are confirming that 2002p2 and 2004p2 don't negotiate well, it means they didn't negotiate well with PoE (15w) either, they worked with 15w. Problem is that these sets are capable to run with 15w...
Hi all,
Recently our lan have been upgraded with Cisco switchs with PoE+. Since then, everyday we find 2002p2 and 2004p2 complitily frozen.. Users can't dial, the clock is also frozen, they can't get incoming calls.. The only solution is to restart them. After that the phone is again fully...
Hi Rickypone,
Yes, there's a QSIG trunk between the CS1000 and Siemens SIP endpoint.
When Siemens calls Nortel there is RTP in both directions.
I'm sure it's application/qsig that originates the issue.Siemns endpoint only needs SDP to proccess media.
How could I disable application/qsig in...
Hi everyone,
Some of you helped me in my previous post (long post-dial delay), and I am very grateful for that, but I'm afraid that I need your knowledge and wisdom once again.
The scenario is the same. My CS1K v5 is interconnected with an OpenScape Branch (Siemens) through a QSIG to allow...
Guys, I could fix the problem.
The issue was in siemens side. I had to set it's overlap options to 5 digits. Now when Nortel dials without # the call reachs Siemens end without delay.
I dont really understand but its ok. Now it works.
I want to thank all of you for ur help and time.
Good morning,
I've made the test calls.
Nortel calling Siemens without #:
DCH 9 UIPE_OMSG CC_SETUP_REQ REF 000000B8 CH 29 23 TOD 9:23:35 CK 8E374413
PROGRESS: ORIGINATING END IS NOT ISDN
CALLING #:2633 NUM PLAN: E164 TON: UNKNOWN
CALLED #:14561 NUM PLAN: E164 TON: UNKNOWN
DCH 9...
I understand you, but why if do I add # after the 5 digits this problem doesn't happen? As far as I know, # tells to the CS1K that I am not adding more digits and it can sending the call to the destination, right? And if I am not wrong, the destination end doesn't receive # in the signaling...
Hi bignose21,
thank you for ur time.
On monday I will test again. I'll capture on the receiving end while CS1k phone is on that 16 seconds delay after dialing, and by this way we will see if the call is stuck on cs1k or it is not well processed by the other end.
Thanks again !
Thank you bignose21 for your help.
OVLS and OVLR are already in YES, OVLT (timer) in 0.
Do you think that EOD timer is what do I need to change? My route has:
TIMR ICF 512
OGF 512
EOD 13952
NRD 10112
DDL 70
ODT 4096
RGV 640
FLH 510
GTO 896
GTI 896...
Hello everyone,
Let me expose the problem:
Our CS1K's DN are 4 digits lenght. we have generated some DSCs with lenght of 5 digits, new route, dch, loop, etc, to reach Siemens's DN (5 digit lenght)through QSIG between both PBXs. Both ends can reach the other, RTP, signaling, no problem, but...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.