Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Terry6868

    Avaya Aura Add second line to SIP Viper

    Good Day, Has anyone done or was tasked to add a second line to a SIP Viper phone if so what option/feature would that be associated with. I know MDA allows you to register an extension on multiple devices but I would like to add an extension to a SIP viper device if possible. A Viper phone...
  2. Terry6868

    Can't dial new DN range from another site

    Dis-regard I found the issue we had to add the CDP for the number range in the UCM under the NRS
  3. Terry6868

    Can't dial new DN range from another site

    Good day, I am programming new phones with a new DN range and internally I can dial the new number range but, one of my sites are getting a fast busy when they try to dial the new number range. The DSC for the new number range on the remote site is pointed at the VTRK connecting the two sites...
  4. Terry6868

    DTA errors

    now back to the original DTA203 errors for each loop...going to say I've done all I can in the PBX and it's a telco issue.
  5. Terry6868

    DTA errors

    The error has now changed to DTA203 3 0 an AIS alarm.
  6. Terry6868

    DTA errors

    Thank you KCFLHRC for reminding me about the clocking. I checked the clocks and found 1 in DTI061 and issued the tracking command to get that back to locked to slot 1 but, I'm still receiving the DTA203 201 0 0, DTA203 204 0 1 DTA203 203 0 2 errors with RAI errors still going up.
  7. Terry6868

    DTA errors

    I would like to know is there anything I can do or is it my telco provider issue. I am getting DTA203 0 0, 1, 2 DTA201 0 0, 1, 2 DTA204 0 0, 1, 2 errors I am thinking it is a far end alignment issue in LD 60 when I do a lcnt the RAI counter was over 2,000 on each one of these loops which I...
  8. Terry6868

    Call Pilot Issue

    Good Day has anyone ran into an issue where your two DNs associated with the operators go straight to voicemail instead of ringing out if you call them directly. They are idle and you can make calls from them MSB is not enabled or call forwarding.
  9. Terry6868

    PDT session only when using putty

    Firebird an INI. did the trick thanks so much for your assistance.
  10. Terry6868

    PDT session only when using putty

    Thank you Firebird I will give that a try.....
  11. Terry6868

    PDT session only when using putty

    Thanks Firebird for the response but, when I'm in PDT and I do devs I see the PTYs 16 of them are these not part of the 3 configured PTY on the PBX? I also notice that when I login via putty it always grabs... 19 /pty/ptty08.S 19 /pty/ptty00.S 20 /pty/ptty00.M 19 /pty/ptty01.S 20...
  12. Terry6868

    PDT session only when using putty

    Good day gentlemen have any of you ran into the issue of PDT login when using RLOGIN via putty and seeing SL1input not defined.... I can't exit out of PDT (using: sl1input) and get back to the CS login screen. When I try to login I'm always taken to PDT prompt and can't exit out. When I login...
  13. Terry6868

    Datapulse Intuition 1000 console ODBC issue

    @FirebirdScrambler...yes, I did the good ole stare and compare and I mean all their settings match. I sent an email to datapulse and they suggested that it is a services issue that is all they could tell me without a renewal of the maintenance contract and the client isn't in a hurry to do that...
  14. Terry6868

    Datapulse Intuition 1000 console ODBC issue

    Thanks FirebirdScrambler I did check the SQL settings via the SQL manager for each console and all the processes are started and sharing is enabled I'm stumped as to why this one isn't working. The only reason they haven't noticed is because they were not using the ODBC database within the...
  15. Terry6868

    Datapulse Intuition 1000 console ODBC issue

    Hello, I have 5 operator consoles and one is not sharing the updates of the ODBC. When the other 4 consoles add a new user the change is saw instantly. The one that is not working doesn't show the folders or the people added by the other consoles. I have checked the ---> Open Data Sources...
  16. Terry6868

    Corporate Directory CS1000 7.5 Issue

    Thanks FirebirdSccrambler for this info it clears up things....I'm storing this information just in case the clients here change their minds on implementing corporate directory I'll be ready to go. I'm definitely going to checkout "zoc" out thanks again :> have a great day!
  17. Terry6868

    Corporate Directory CS1000 7.5 Issue

    Yes, FirebirdScrambler it is the most recent one I deleted the old one out of PDT...did the process over again and it's there. I read on another thread that someone changed from zmodem to xmodem and they didn't get the CCCCCC timeout error. but for the life of me I went through my putty...
  18. Terry6868

    Corporate Directory CS1000 7.5 Issue

    Thanks bignose21 I did and nothing changed. I just tried to load the directory from PDT and got an error of too many receive timeouts guess this is why the file isn't showing up on the phone. Now I need to know has anyone ran into this and is there an area I need to check.
  19. Terry6868

    Corporate Directory CS1000 7.5 Issue

    Does anyone know what could be a possible issue is to why my corporate directory on the phone shows "Directory Unavailable" In the UCM subscribers are there I went to the corporate directory table configured and ran report next logged into the CS1000 went to the PDT level found my CpDir0.csv...

Part and Inventory Search

Back
Top