  1. Mikhen

    TM Problem

    Hi Norbert (snor), Thanks for input No I have nothing conflicting with the daily storing to disc of TM data as of my knowledge, automatic dump runs at 22:00 changed that from 23:00 to be sure. I usually copy TM files to external storage and delete the files on disc every other month or when we...
  2. Mikhen

    TM Problem

    Hi Satellite1900, A HIMDP for Lim 1 and a HIEDP will be provided here among other. How do I create a spoiler that can be closed? Just for you below Satellite 1900 tell me if you need some more information. <IODDP; I/O DEVICE DATA NODE IODEV/SUBFS BPOS/EQU I/O-BUS...
  3. Mikhen

    TM Problem

    Hi again, No idea what the solution can be? Cleaning and doing changes to active measurement (TM) didn´t help still same problem. 294 TRAFFIC RECORDING INTERNAL MEMORY DATA ERASED - MIDNIGHT DUMP DATE TIME ALP NOIF UNIT INF1 08NOV17 00:11:00 6 1 0 Looked...
  4. Mikhen

    TM Problem

    Hi himdp, And thank you for your input Probably Sattelite misunderstood yet it´s not his fault but mine. Ok so "Pre" is the one to use, thank you. Ok so the problem is something else then. I´m cleaning my TM measurements anyway now so we can only wait and see if the problem disappear. Any...
  5. Mikhen

    TM Problem

    Hi Satellite, Thanks for answer Ok so Addinfo1= 0 equals "User Interrupt" I didn´t know (couldn´t find it) that piece of information though I searched Alex We have some menos (TM) running until 24:00 do you think they could cause this even though the 294 alarm always occur at 00:11? Example...
  6. Mikhen

    TM Problem

    Hi all, I have a problem that we get an 294 alarm now and then, Se below, always at the same time. We have no other alarms that can be related to this like buffer alarms etc (See alarm log). When we look at ´the content of TM catalogue we can se that for the days this alarm occur that TM files...
  7. Mikhen

    False B answer?

    Hi all, I have a problem when calling a mobile phone belonging to say operator Telenor and when trying to leave a message the call is disconnected with a voice saying something like - Couldn't leave a message, the call will be disconnected. The thing is that this doesn't happen everytime but...
  8. Mikhen

    Cannot synchcronize EMG with MD110 and other &quot;related&quot; problems

    Hi again. An update I did some testing of group Switch, See below. <GSFTI:GSM=0,GSSIDE=0,TEST=SLOT; GROUP SWITCH MODULE TEST FAULTY TIME SWITCH = 0 GJC = 1 TIMESLOT = 17 FAULTY TIME SWITCH = 0 GJC = 2 TIMESLOT = 19 CONNECTED LIM NO= 6 IS FAULTY FAULTY TIME SWITCH = 0 GJC =...
  9. Mikhen

    Cannot synchcronize EMG with MD110 and other &quot;related&quot; problems

    I have got a problem with synchronizing EMG with MD110 and get a lot of command lost a lot and thus synchronizing fails also cil data fails from time to time. System running is: VERSION=CXP1010105/4/TSWSP04/R5A It is a 10 LIM system I also get alarms that I think is related to this problem...