Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations IamaSherpa on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. troidus

    Trying to swap two 008 MLX cards for 016 MLX cards

    I succeeded, but neglected to come back in here to update the thread. I was able to replace the 008s in slots 9 and 10 with 016s. This caused all of the station port and adjunct numbers past slot 09 port 08 to change, but left all of the programming and labeling in place on the ports. It...
  2. troidus

    Trying to swap two 008 MLX cards for 016 MLX cards

    That'd be nice, but that'll have to wait until the company decides to replace the phone system. Once I've moved the MLX sets (and two BIS-22 sets that are being upgraded, down from 23 that had been in service) that are scheduled to move, I'll still have 18 MLX sets and 29 active T/R ports on...
  3. troidus

    Trying to swap two 008 MLX cards for 016 MLX cards

    Thanks for that, and I've used that method before on the other switch that has no SMDR, but I usually just Print the Ext Direct. (Finally got WinSPM installed on the log server over there and have used that to dump info via the Admin port, so no more manual reports.) I actually have really...
  4. troidus

    Trying to swap two 008 MLX cards for 016 MLX cards

    LOL. Thanks for that visual. The modules haven't been touched since 2007, and never by me except to replace failed ones. I'm trying to get everyone in the main building on the same switch, but I can't quite get there with what I have, which is why I want to swap out the two modules. Some of...
  5. troidus

    Trying to swap two 008 MLX cards for 016 MLX cards

    OK, so I did some math. Using the default load numbers, the second and third expansion chassis are out of spec as is, at 108 each, and the first is close at 94.5. Calculated loads based on what's plugged in are much better, at 56.6, 70.2, and 61.5. Loads from my first attempt (which really...
  6. troidus

    Trying to swap two 008 MLX cards for 016 MLX cards

    OK, I found the tables in this document, the Magix Installation manual. http://downloads.avaya.com/css/P8/documents/100013686 Now I'm off to do some math.
  7. troidus

    Trying to swap two 008 MLX cards for 016 MLX cards

    Thanks for the quick response. Where can I find these load tables? I generally have only MLX-10Ds installed, so I definitely don't have a large per-station load, but if the ports themselves are a problem, then I'll have to figure out how to rearrange them. My first attempt at installing...
  8. troidus

    Trying to swap two 008 MLX cards for 016 MLX cards

    Good afternoon, everyone. Have a Legend chassis running Magix Release 4.0 v7.0 on a CKE4 processor. All 17 slots are full, but it's not yet at 200 station ports. I was hoping to change that by replacing two 008 MLX cards in slots 9 and 10 with 016 MLX cards. Got the cards in and did a...