Hey All,
I am trying to program toll restriction on the NEC SL1100. Looking to only have 911 calls allowed. Could someone please assist with this? Thanks so much!
We are using SIP trunks and numerous DID's that are directed to different auto attendants. I have set-up a mobile extension and paired it with the digital extension. All works with speed dials and outbound call to cell number its associated with. My question is how and where do I go to program...
The only default "backdoor" password for the DS series is 372000. This was the installer level password. There are also 2 other system user level passwords. Sys Level 1: 0000 and Sys Level 2: 9999
This is becoming a more common issue with Windows 7 devices. Either try reinstalling System Admin one or more times, (I know it sounds repetitive but can work)or you can try another version of the admin. See if you can log into the manager via web using the system ip address. You can also run...
Greatly appreciate your response!
However, I don't follow. Assuming these keys you are referring to are in 15-07?If so, I don't see any keys titled that. Sorry for my confusion. The SL or SV is a bit new to me. I have been a DS/DSX guy for quite some time. Any further insight?
Thanks again
I have an application with SIP Trunks, DID's, auto attendant and multiple companies. Have all working fairly well but question I have is this. I have set-up Virtual Extensions to act as call coverage keys. The VE is busy (in use) so when the next call comes in to that virtual extension no-one...