Thanks for the suggestion. Since I'd gotten no replies, I went to another forum. The answer was to make an adjustment to my OVRPRTF. Instead of OVRPRTF FILE(INVPRT) TOFILE(&DVDTO), it needed to be OVRPRTF FILE(INVPRT) SPLFNAME(&DVDTO)
I am trying to call an RPGLE program from a CL four times. The RPG program has one output file defined and, based on the parameters passed, determines from the input file which records to write. It works fine, but I need it to write to four different spool file names (OTHPRT, OTHKSPRT, FMFMPRT...