Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. PHANDL

    Mass Call Spam / DDOS on NOrtel 81C

    To start I am running a Nortel 81c. Yesterday afternoon, the building I work in received some sort of mass spoof call. All the phones in my building were ringing at the same time and received a call from from the same number tying up all of our trunks. I know how to reroute the specific number...
  2. PHANDL

    Checksum Test Please Wait

    Is it possible the switch went bad? The consle, gateway, server, and modem are all connected through a Netgear 8 port switch. Also the pri loop running from my main Nortel switch is not seeing the distant end which would be the Avaya switch.
  3. PHANDL

    Checksum Test Please Wait

    Yes a card on the gateway has a red alarm, I believe it is the system card.
  4. PHANDL

    Checksum Test Please Wait

    Hello all, I am new to the Avaya CM my only real experience is performing basic administration on the switch such as name changes and assigning new numbers. Our Avaya switch recently overheated due to the A/C system going down in our building. The AC has been fixed and the room is now cooled...
  5. PHANDL

    Integrated Conference Bridge Issue

    Alright, it is working again. It was user error, I forgot to transfer the security device from the old card. Thanks for your help!
  6. PHANDL

    Integrated Conference Bridge Issue

    I am connecting to it using our terminal now. I set up the connection for vt100 9600 baud data bits 8 stop bit 1 no parity and no flow control it allows me to type but there is no response. I am entering the keycode like the implementation guide says but I get no response.
  7. PHANDL

    Integrated Conference Bridge Issue

    It seems I cannot do anything through putty, it allows me to connect but i cannot enter any commands. I set the interface parameters as stated in the service manual but still nothing.
  8. PHANDL

    Integrated Conference Bridge Issue

    That is what it is then, I have not configured it. The only issue is we do not have a laptop to serial in, I have borrowed one from our network guys but cannot figure out how to access the card to configure it via the laptop serial connection. Do I need special software or should I be able to...
  9. PHANDL

    Integrated Conference Bridge Issue

    I cam in this morning and both of our ICB cards were down. I was able to get one of them up by disabling and reseating it. The second card had to be replaced with a spare, when I put in the new card it appears to come up and the red light clears when I enable it but I am unable to connect to...
  10. PHANDL

    Incoming PRI Issue

    Yeah, I used one from a new call. My terminal is a standalone so I have to type the messages out. Its the same outgoing message that comes up for each call.
  11. PHANDL

    Incoming PRI Issue

    Here is what the RDB of the PRI in question looks like, I noticed ISDN is set to yes and there is no DSEL option. TYPE RDB CUST 00 ROUT 0 DES DSN_NI2_PRI TKTP ATVN NPID_TBL_NUM 0 ESN NO RCLS EXT VTRK NO NODE DTRK YES BRIP NO DGTP PRI ISDN YES MODE PRA IFC NI2 SBN NO PNI 00000 NCNA NO NCRD NO...
  12. PHANDL

    Incoming PRI Issue

    when i prt RDB there is no IDC shown so I am assuming I do not have IDC tables setup here.
  13. PHANDL

    Incoming PRI Issue

    Could this be caused by something in the RDB?
  14. PHANDL

    Incoming PRI Issue

    How do I look at the IDC table to tell whether or not they are in the same entires?
  15. PHANDL

    Incoming PRI Issue

    Here is the outgoing message: DCH 40 UIPE_OMSG CC_SETUP_REQ REF 00000A52 CH 40 23 TOD 11:59:49 CK 086F8D16 PROGRESS: ORIGINATING END IS NOT ISDN CALLING #:2352621 NUM PLAN: PRIVATE TON: UNKNOWN CALLED #:2351002 NUM PLAN: PRIVATE TON: UNKNOWN PRECLEVEL: #4 - RTN DOMAIN: 000000 DCH...
  16. PHANDL

    Incoming PRI Issue

    Going to turn outgoing on also wil post once it is done, thanks.
  17. PHANDL

    Incoming PRI Issue

    Only have the incoming messages on, all outgoing calls are working fine.
  18. PHANDL

    Incoming PRI Issue

    Here is the message for 2xxx DCH 40 UIPE_IMSG CC_SETUP_IND REF 000008E4 TOD 13:14:32 CK 792F56E2 CALLED #:2*** NUM PLAN: UNKNOWN TON: UNKNOWN CALLING #:2352*** NUM PLAN: UNKNOWN TON: UNKNOWN PRECLEVEL: #4 - RTN DOMAIN: 000000 DCH 40 UIPE_MSG CC_ALERT_IND REF 000005BF CH 40 23 TOD...
  19. PHANDL

    Incoming PRI Issue

    Hello everyone, I am having an issue with out Nortel 81c switch that has been ongoing for a few months now. The issue is with one of our DSN PRI trunks. When there is an incoming call on DSN it works for all extensions in the range of 2000-2999 but when an incoming call is made to extension...
  20. PHANDL

    Picking up a Call on Hold with an Analog Line

    Here is the situation, I have an executive who has an analog phone in his office. His secretary has a digital phone and has the executives main number programmed as a secondary line on her phone. Whenever the secretary answers the line and then puts it on hold the executive is unable to pick up...

Part and Inventory Search

Back
Top