Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Chris Miller on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. HKLord

    Micros Res 5.0 New Connection String?

    No, I'm referring to the .db file itself. I've identified one problem... it's a 64 bit system, and all the drivers are 32 bit. So, I had to link to the 32 bit odbc driver administrator to see the Micros ODBC drivers. I *think* the answer is goign to involve setting up a 64 bit obdc system...
  2. HKLord

    Micros Res 5.0 New Connection String?

    Hi all, We've just taken our first set of Micros Res 5.0 systems, and now my connection string seems to be broken. This is on a new system, running Windows Server 2008 R2 and the new Micros Database runnign on SQL Anywhere 11 as well. From what I have found out about it online, it appears as...
  3. HKLord

    Micros 3700 Menu Level Pricing to Ticket Menu Item

    Wildbar, Thanks for the input as well. No, it is a standard issue that all restaurants should be facing if they are pouring alcohol. In our case, it is for multiple brand name concepts and all of them have the same basic configuration. The system was configured by the experts at Micros, and...
  4. HKLord

    Micros 3700 Menu Level Pricing to Ticket Menu Item

    This is basically the solution that I came up with as well. The missing piece for me was the lack of the trans_dtl.type. Once I had that, I could link like you were showing. Thanks for verifying my analysis!
  5. HKLord

    Micros 3700 Menu Level Pricing to Ticket Menu Item

    Thanks Megan, I figured that I had it... I included mi_dtl.price_lvl and chk_dtl.rvc_seq the other key seemed to be that I needed to join out on the dtl_type and transaction type The system was set up so that the rvc_mlvl_temp table has the pricing for Regular, Up, Rocks, and Double (from the...
  6. HKLord

    Micros 3700 Menu Level Pricing to Ticket Menu Item

    I'm having some problems joining the Ticket Information back to the Menu Item and ultimately back to the mlvl_type to determine the volume of a pour. The rvc_mlvl_temp has two categories "M" and "S" for the mlvl_type. That difference is preventing me from joining the menu item to its mlvl...
  7. HKLord

    Micros 3700 Clock In hook

    3700SIMComp_man is not in the directory. We also checked on several of the deployed systems to no avail. I found a copy online, but am still following up with Mircos to get a legit copy. I do not have installation disks or anything else, as the systems were set-up by our rep/vendor/reseller...
  8. HKLord

    Micros 3700 Clock In hook

    Thanks, that has started me in the right direction! Now, since I get to learn this scripting language, does anyone have a copy of the 3700 System Interface Module (SIM) User’s Manual? I found the SIMHelp.chm and the other generic documentation right where it is supposed to be, but no luck on...
  9. HKLord

    Micros 3700 Clock In hook

    Hello all! I'm new here, and have recently been thrown into the deep end of the pool with assisting on writing an application to allow us to clock employees into micros from an external source. What we need to do is : 1. Create a tool to allow us to open an external website (the pay tracking...