compare with both SBC and SM sent out PPM: getHomeCapabilitiesResponse, the primary SM has both SM 1 & SM2 inside PPM, but the PPM sent out via SBC only has SM 1. I already set up 2 x PPM mapping and reverse proxy with the corresponding interface in SBC.
i tried to set up 2 pairs of connections.
sample. 1.2.3.4:5071 NAT to B1, 1.2.3.4:5072 NAT to B2.
and 46xxsettings.txt
SET SIP_CONTROLLER_LIST "1.2.3.4:5071;transport=TLS,1.2.3.4:5072;transport=TLS"
but doesn`t see the workplace registered to second SM.
Hi all,
I got a question about the solution as below,
Normally remote worker registration to SM-A is working fine, but once SM-A down, the remote worker registration message keeps sending to SM-A when tracing SBC, although got the SM-B as the second priority setting in the SBC routing profile...
Hi all,
I got the situation now is the SBC OVA 8.0 HA installed in 3 different AVP platform, everything is working fine.
The problem is the network connectivity to SBC primary which A or B is going down such as physical disconnected or switches down, supposed will be trigger failover, but no...
Does anyone tried / experience to only allow CM phone to call a few designated external numbers, otherwise, except internal extension all denied? Many Thanks
Hi kyle555,
Any idea why can`t login Devices Services on Equinox, but i can use the same account login over AADS web admin "8445/admin". sip call , IM is work fine now. except contact services. Thanks
kyle555...Thanks for your kindly clear explanation
Both AADS & SMGR LDAP sync ldap from my lab Window AD and map attribute with mail. i can login DS in EQX with my email address and get my extension return. once logged the DS service, contact services going unavailabe.
i`m beginning to the Aura 8 UC platform from lab, Equinox window client working normally registered to session manager, the first problem coming up after login AADS, contact service changed to unavailabe. could anyone advise to figure out the problem is?
Hi,
i got the situation that physically disconnected SM connection then CM signaling group still keep to in-services status last for at least 5 mins, checked with the SIP OPTION sent from CM to SM only every 15 mins, is it possible to tune it faster? Anyone can help? Many Thanks
Anyone can...
Dear Bros,
Any idea can have the monitor key on 1600 series phone for analog trunk ?
my client would like to have an key to dial out from analog trunk directly by one touch ,but it can not press to answer , it`is possible?
Otherwise, IPO IP Phone can split to different group setting for...
Hi Westi,
Tried the shortcode s1234567E, the calling number passed by the tie system didn`t trigger the shortcode e (extension) happening...captured on the monitor only sent out the calling number was 1234567.thanks for your helping..
Hi intrigrant,
The shortcode are working for pass the calling number to the IPO..but only 3 digit and the tie system can`t config to pass fully 8 digit.Any method to combine the calling id to the prime numebr 123457xx ??
example : TIE system pass the clid to the IPO that is 777..and local PSTN...
Hi Westi ,
Already separate the main ars table .for the main ARS table placed a Ns123456e is work fine for local site can show correct clid but for the T1 QSIG also placed the Ns123456e shortcode on the line to bypass the ARS table then make outgoing call directly..only can show the prime...
Hi intrigrant ,
Yes,i would like to make outgoing call from remote site over the ipo T1 PRI connect to PSTN,i had planed the DDI Level for the local site was 8xx and remote site was 7xx and call from local site will show the clid 1234567xx ,and i hope the remote site also can show it to...