Hi....
I guess, it depends upon the type of the extensions,,,, Analogue,Digital, DECT...
for example if you wanna make a quiry about the entire programmed analog extension in your system:
EXDDP:DIR=ALL;
KSDDP:DIR=ALL; ....> for Digital.
SYEDP:BPOS:1-1-40; .... Vacancies on this Board...
Hi Dear engalfawaz. . . .
her is an examples how to configure trunks
1. TLU75 Analogue Trunks
ROCAI:ROU=1,SEL=011000000000001,TRM=7,SERV=2100000000,TRAF=00151515,SIG=400000000000;
RODAI:ROU=1,TYPE=TL11,VARC=00000022,VARI=00000108,VARO=00002015;
ROEQI:ROU=1,EQU=1-0-50-0,TRU=1-1...
Hi Everybody,,,
Can I replace the faulty PU4DC board with new RG5DC board???
If no, why please????
If yes, is there any important procedure I must take in considerations before the swapping????
Thank you