Try this
Give a unique extension number in 11-19 for Conf Group 1,
Give this grop a name if required in 20-34-01,
Set a password for the group
Set the maximum number of participants
Set up an indial number if required.
Callers now can call directly to the number in 11-19 or the indial number...
There was a issue where a cleardown was not detected or sent to the CPU. This caused the extension to remain busy as far is the CPU was concerned. The fix was that Rtp stream was monitored and if it was only in one direction then a forced cleardown signal was sent to the CPU. Not sure of...