All has been resolved.
Ended up being an issue with PNI.
They were a mismatch.
The ISDN (local PRI) was set to 00000 for the PNI
The TIE to Cisco was set to 00001
Changed them to 00000 so they would match and "BOOM" all is working properly.
Thank you all,
CommoGuy101
I have it resolved finally.
Turned out that the PNI for the local PRI was set at 00000 and the PNI on the TIE trunk was set to 00001
Changed the TIE to be 00000 and all is working properly.
Thank you all for your input and help.
CommoGuy101
The TARG on the TIE route is open completely.
No TARG entered
When doing a trace on the d-Channel, which D-channel...the one for the local PRI or the TIE trunk should I look at ?
The weird thing is I can send it over a TIE to a remote Nortel system and then route it to CISCO using a TIE on...
FRL is set to 0 on the routes
Changed the settings for the NCOS
Still getting the same results.
Extensions on Nortel can call extensions on the CISCO using the CDP routing.
Only fails when a call comes in on the local PRI then trying to route via CDP to the CISCO.
CommoGuy101
Both of those are set to"YES"
When calls come in on the Local PRI, I can CDP a call from Nortel CS1000 to another Nortel, proving that trunk to trunk transfer is working.
But when I CDP to the QSIG connected to the CISCO the call is diverting to the attendant console.(as if it doesn't even see...
I checked the CDB and those were already set to yes
DITI YES
TRNX YES
EXTT YES
FTOP FRES
When I check the ESN I have noticed that all were set to 0
When I look at my other sites those are set 0-,1-1,2-2 and so forth
NCOS 0 - 0
NCOS 1 - 0
NCOS 2 - 0
NCOS 3 - 0
NCOS 4 - 0
NCOS 5 - 0
NCOS 6 - 0...
I have tried changing the DDTI to "yes"
I get the same results
Calls are diverting to the main console.
I should also say that there is a TIE trunk between to Nortel CS1000 and Nortel Option 11.
The calls work properly when CDP to the to the Option 11.
All looks like the same set up to me.
I...
Morning everyone,
I have an issue with trunk to trunk transfer...I believe
I have a local PRI on my Nortel CS1000E with a block of 100 DID numbers
Recently, I have set up a TIE trunk between the Nortel and Cisco.
I have taken a DID number and then did a CDP of that number to the Cisco system...
Morning everyone,
I have an issue with trunk to trunk transfer...I believe
I have a local PRI on my Nortel CS1000E with a block of 100 DID numbers
Recently, I have set up a TIE trunk between the Nortel and Cisco.
I have taken a DID number and then did a CDP of that number to the Cisco system...
After I did n INI, I was able to successfully FDL the TMDI card.
I can enable the loop and Dchannel and perform a loop back
Now I am at the point where I think I need to do the clocking.
I have placed this TMDI in a carrier that no other PRI is installed or a clocking source
I don't have a CC...
Release 7 is what I see
I have done in this order
RST TMDI 4 1 1
SLFT TMDI 4 1 1 (test pass)
ENL TMDI 4 1 1 FDL
Hate doing an INI and not sure that will even solve it.
REQ iss
VERSION 4021
System type is - Communication Server 1000E/CP PM
CP PM - Pentium M 1.4 GHz
IPMGs Registered: 3
IPMGs Unregistered: 0
IPMGs Configured/unregistered: 0
RELEASE 7
ISSUE 00 Q +
IDLE_SET_DISPLAY Lodi Community Hospital
IPMG TYPE CSP/SW MSP APP...
After the RST command, I have done the slft tmdi 4 1 4 and all passes
SELFTESTS PASSED
CARDID= NTRB21AA
How can I determine what type of cabinet, chassis?
When I do the RST TMDI 4 1 4 I do get the OK
However if after that I try to ENL TMDI 4 1 4 FDL it just sits there.
After it sits there for so long, I am able to **** out of the load but nothing has taken.
I have let it timeout as well.
Still don't get a n active TMDI
.stat tmdi
TMDI 000 0...
I originally built this on 0 1 5 and was getting the same issues.
So I moved it to an open slot 4 1 4, after outing everything and then re-adding it all.
I still get the same results.
Are there specific slots I am to use for TMDI?
Hello All,
I am having some issues enabling a TMDI card.
I have built the DLOP in the CEQU
Built the DCH
Created the Route
Add the TIE members
Clocking is set up
stat TMDI and I see:
.stat tmdi
TMDI 000 0 1 ENBL
TMDI 000 0 2 ENBL
TMDI 004 1 4 MAN DSBL
I have tried to enl TMDI 4 1 1...
Hi All,
I am having some issues today pinging my default gateway on the Nortel CS1000
I have a route built and active:
0.0.0.0 to 137.135.128.1
I am unable to ping this IP address.
All of this was working properly.
We had a hub go out and moved the connections to a switch.
I am not sure if there...