Well move went OK all in all, a few other dramas occured but all good. I have here the error table, would be handy if anyone could cast their eyes over it and tell me what these faulst are likely to be related to.
PRE-MOVE PABX DUMP
----------------------------------------------------...
What a score, have found maintenance manual in an unused filing cabinet adn it appeasrs to haev a logon code.
Will try that tonight and the LET A command to see if I can generate a list of faults, it also gives me a list of numbers that supposedly react to various devices.
Fingers crossed.
Bad news unfortunightly. Both of the suggested logons didn't work which was a bit gutting. At a bit of a dead end I think on this one.
Not sure if anyone has any other suggestions they can chuck in the ring.
Looks like we'll be moving it with caveats. Fiil you in Wed with how the move goes...
Thanks for that. I will give it a try Sun night when I am back on site.
What I really need following that, and assuming you can do this from user level access, I want to see what errors/faults are present on the system as the Major and Minor Fault lights are lit and I'd like to know what they...
Thanks for the speedy response, and yes I did get a little lost. Below is the dump from my hyperterminal session last night.
Unpublished Work. Copyright Siemens plc.
All rights reserved.
DX DSGHF5765 31765.01 01.004
6.3.001 0001000 UK 12 08/11/99 A M 150
18/06/09 02:20:28
OSL, PLEASE.
...
Hiya, well after a delay I finally got back there and hooked in. Got to OSL prompt as you explained. Obviously need some guidance from there. How do I test if a username and or password has been set and or changed from default? I type OSL and it prompted for User, Level etc. which I typed in...
Thanks Pablo100 and happymal. I understand the dangers as I move and reconfigure some interesting comms systems and understand the risks, especially on existing standing installations some years old as this one is, and as for a maintainer..... a whoooo???
The unit is moveable. The unit is...
I need to perform a dilapidation report on a Realitis DX. It needs to move about 5m in a CER but 5m is 5m. I will need to shut it down, unplug and move it. Pull the cables back from existing location to new location in new CMS. At the moment the unit has the Minor Fault Light and the Major...