Mr.TeleLion,
Im sorry,our system is TSWSP4.
<CADAP;
CALENDAR DATA
IDENTITY=SABIC-HQ
VERSION=CXP1010104/4/TSWSP04/R5A
16:18:49
THU 03 SEP 2009
END
</****** END OF PRINT ******/
Can u give the configuration of MD side(ROCAI,RODAI,RODDI,RODDI,RINII,RINIP)if possible can u give me also...
Mr.TeleLion,
Can u check if my configuration is right.
RODDP:DEST=ALL;
EXTERNAL DESTINATION ROUTE DATA
DEST DRN ROU CHO CUST ADC TRC SRT NUMACK PRE
71 70 160610000000125000600000000 0 3 0
<RODDP:DEST=ALL,IPOPT=YES;
EXTERNAL DESTINATION ROUTE DATA...
Im sorry,our system is using TSWSPO4 not MX-ONE.
<CADAP;
CALENDAR DATA
IDENTITY=SABIC-HQ
VERSION=CXP1010104/4/TSWSP04/R5A
16:18:49
THU 03 SEP 2009
END
</****** END OF PRINT ****
Mr.Telelion,can u give me the step by step configuration i n MD Side (ROCAI,RODAI,RODDI,RIANP,RINIP) and if...
Hi Again,
As usual I have problem again.We are configuring IP Trunk between Saudi and USA.In Saudi we are using MX-ONE SP4 and in US they are using AVAYA.Can somebody give me the step by step configuration in AVAYA and in MX-ONE.
Thanks in Advance
hi everybody,
please help me in my problem.we have a IP (Networking)Trunk here in jeddah and dammam,saudi arabia.we are using Ericsson Consono.Both Consono connected via IPLU CARD.If the caller from dammam call to jeddah,the call goes through but jeddah branch call in dammam,i see the telephone...
I want to access one of our sites in my house via modem.I call the technician to remove and re insert again the NIU,after re-insert the NIU,I can acess the MD but after 5 minutes when I will access again.I cannot access.
IOPWP; (To print the password)
IOPWC:AUTH=7,PSW=_______; (To change the password (BC9).
To remove the system password associated with authority class 1.
IOPWC:AUTH=1;
For BC13 AND UP:
To change password of auth.7.
Signin in highest category (cat.7)
1.IOUAP...
Is this happen on all analog extensions or only one extension,if this problem happens only on one extension,try to change the tel.set or restart the program unit for analog,RFPUI:LIM=location of analog extension,UNIT ELP6,restart the board RFBOI:LIM=X,BPOS=X-XX-XX;and then...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.