Our organisation has a growing network with the result that we now need more IP's ie another class C, so I put another NIC in our PDC and BDC. The present configuration now looks like this
PDC NIC 1 - 200.5.5.10 255.255.255.0 Gateway 200.5.5.37
PDC NIC 2 - 200.5.6.10 255.255.255.0
BDC NIC 1...
Thanks for all the assistance and ideas, the problem is solved. It turned out to be the media converters which by default (for reasons only known to the manufacturer) were set to half duplex. I pulled them apart switched the jumpers and hey presto 1 100BaseT LAN working like a dream.
Regards
Rewas
Thanks for your response<br>
<br>
By significant = appears to be every packet sent, although not measured with a Fluke or similar the orange collision light on the hub and the switch is on all the time with some brief flickering in the following scenario<br>
<br>
Server - full duplex 100Mb with...
For MS Proxy install the proxy client on the workstation activate it (from the control panel) an there should be no problem. Ensure that in MS Proxy on the server that you are aware how clients connect ie via computer name or IP and make sure the client is configure the same way. You will be...
I am experiencing significant collisions on a 100BaseT network when just one Wintel computer on the lan is recieving packets from a NT Server (4.0). As more computers are switched on more collisions occur. The nic on the server is set to auto the same as the workststion. I have connected the...
I am experiencing significant collisions on a 100BaseT network when just one Wintel computer on the lan is recieving packets from a NT Server (4.0). As more computers are switched on more collisions occur. The nic on the server is set to auto the same as the workststion. I have connected the...