  1. granthbr

    Sonicwall VPN appliance - connection drops when user connects domain

    Updating the firmware/Software seemed to take care of the problem. ( this is a little strange because I have four other similar VPNs with the same firmware and they never had any issues like this).
  2. granthbr

    Sonicwall VPN appliance - connection drops when user connects domain

    By pass through I meant that NAT is turned off and DHCP is disabled. So, it is passing traffic straight through. Sorry for the unclear description. I will try to update the software and get back to you. Thanks.
  3. granthbr

    Sonicwall VPN appliance - connection drops when user connects domain

    Thanks for your interest. The Firmware is SonicOS Standard 3.1.0.7-77s. The VPN appliance is a Sonicwall VPN TZ 170 Standard. The remote clients are a running Windows XP. I believe IKE is the security protocol ( IPSEC). Please let me know if more information is needed. Thanks!
  4. granthbr

    Sonicwall VPN appliance - connection drops when user connects domain

    I have a Sonicwall VPN that disconnects when users on the remote end connect to the Windows 2003 domain ( the appliance must be reset for the connection to re-established). I tested the appliance outside of our network locally and did not encounter any similar issues. The ISP insists that the...