Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. saxman52

    Panasonic KXTDA200 KSU

    I just read in the installation manual about the power supply replacement procedures and also the possibility of having to replace the backboard. That is why I'm trying to just get a complete replacement cabinet with power supply.
  2. saxman52

    Panasonic KXTDA200 KSU

    I have a client with a Panasonic KXTDA200 KSU that has died on them. They checked the UPS outlet and AC plug, and both are OK. I am trying to make arrangements to get another KSU, then reinstall the CPU and cards, but has anyone had this happen to them before, and were you able to fix the power...
  3. saxman52

    NEC SV8100 Digital set cable distance extender

    I'm actually going to the customer site today, and will take all of the junction points out of the cable, as it running through 3 IDF's, to see if I can get it as one piece of copper from point A to point B. The analog solution is a good idea, and I will mention it to the customer, but they had...
  4. saxman52

    NEC SV8100 Digital set cable distance extender

    Thanks for your reply, I had hoped to avoid going IP, but it looks like there is no other option.
  5. saxman52

    NEC SV8100 Digital set cable distance extender

    Has anyone successfully installed a NEC DTL digital set, further than the recommended 1800 ft distance, using a booster device (i.e. a transformer) I know that there was a way to do this on the old Nortel systems. I checked with NEC tech support, and they weren't quite sure, and didn't have any...
  6. saxman52

    Call Pilot 100 on a 8x24 DR5

    I have set-up a Call Pilot 100 on a DR5 8x24 as a test. All feature codes are active (FXtest). I know that Nortel wants 4.1 or better. Has anyone been sucessfull with a DR5 integration? Are there problems with call transfer, off prem transfer etc. Look forward to the responses.
  7. saxman52

    Call Pilot 100 on a DR5

    I have installed a Call Pilot 3.0 on to a DR5 8x24 as a test. All feature codes are active through xftest. Has anyone been able to do this and does the Call Pilot work properly (ie call transfer, off prem transfer etc). I know that Nortel wants 4.1 or better. Look forward to hearing about this.

Part and Inventory Search

Back
Top