I just wanted to follow up, after replacing the power supply and the carrier/backplane to no avail it turns out that the issue has something to do with the trunk ports on the 408 card in slot 1. Moving the 4 lines lines from the trunk ports on slot1 to any other trunk ports in any other slot...
Thanks for the help. I'm upset with myself that I didn't check this sooner but the same issue exists in any slot other than slot 1. I have 408 cards in slots 1, 2, 3, 4 and a vm card in the end slot. The company moved into the building in March and we don't have everything wired yet so we've...
Swapping the 408 cards unfortunately did not resolve the issue. I did reset and restore slot02 via the operator console, but the issue still remains.
All the tests in maintenance come back fine for either of the 408 cards that I put in that slot.
Merlin Legend 7.0 v9.0 System has been up and running fine for months. This week all extenstions on the 408 GS/LX-MLX card in slot 2 started having an issue where they hear no audio on an outside call (inbound or outbound). The extentions function fine on station to station calls, calls to...