Hi all,
I have an S8400 Server on G650 gateway running R014x.00.1.731.2 software version which died on me all of a sudden. What I think is, it might be the TN8400AP for I have a red light at the top left of the card and a red light at the bottom of the Compact flash card, that’s the middle LED...
Hi AvayaTier3
The serial number under SPE_A which reads 05J223706372 is the wrong one
It should be 057G09228978 which is the one for that processor (TN2404) and the right one
Hope this helps you to assist me please
Thank you
Hi AvayaTier3
Please find attached the screens from SAT
For your perusal and possible help please
Thank youhttps://files.engineering.com/getfile.aspx?folder=4f8746fc-5a6c-4ed7-b977-bc033a38fe1d&file=list_configuration_license_long.pdf
Hi AvayaTier3
Please find attached the screens from SAT
For your perusal and possible help
Thank youhttps://files.engineering.com/getfile.aspx?folder=11f69469-fd83-40e5-aadf-d5382d8ef314&file=list_configuration_software-versions_long.pdf
Hi All,
I have been having two issues with the above mentioned PABX system which arose after a lower version (R011i) was slotted in carrier A.
This led to the processor which was there originally after being slotted back after the removal of the R011i processor picking the lesser software and...
Hi AvayaTier3,
It's the original TN2404 which is there and has been there since we started communicating
I powered it off and powered it back on as you requested
And all the tests passed and finally reset 4 was performed on it
And that's all
Something else, I cannot login while connected to the...
Hi AvayaTier3,
The Serial Number for the original R012 SPE-A tn2404 is: 057G09228978
Also find attached the display capacity screen please
Thank you
Rgds
Josephhttps://files.engineering.com/getfile.aspx?folder=1e26aebc-76fd-4656-a7fa-1242b1c5887e&file=Display_Capacity.pdf
Hi AvayaTier3,
The processor that is active is the R012 tn2404 in SPE-B that has never been replaced and the R012 load is the one the system is licensed for.
The only processor that was replaced was the one in SPE-A which also had R012 software load before replacement. When I removed the...
Hi Guys,
Could I have more lights shed on this issue please
Am desperate for a resolution which I strongly believe you can assist me with
I have attached screen shots from the system in question for facilitation purposes
Thanks in advance
Rgds
Joseph
Hi AvayaTier3,
Please find attached the file containing all the screen shots please
Thank you in advancehttps://files.engineering.com/getfile.aspx?folder=db6e2675-0664-4013-9d4f-88fb7962b029&file=login.pdf
Hi AvayaTier3,
Please find attached the other screen shots please
Thank you in advancehttps://files.engineering.com/getfile.aspx?folder=30e9e884-8cf2-4e5f-a94f-39f75d7f0a04&file=login.pdf
Hi AvayaTier3,
I issued all the commands as you advised and they all passed successfully. However, I wasn't able to return SPE A which is the Standby-SPE to it's former software load of R012i.02.0.111.4 and it's serial number which is 057G09228978 please
I have attached screen shots from the...
Hi AvayaTier3,
Thanks for your quick reply
The Standby SPE is the one with issues
Am able to save translations with no problem but this is only to the Active SPE
May I know which set of commands that I should issue against the standby-SPE please
Is it...
Hi Guys,
It's my believe that there must be someone out there who can be of help to me please
I really need help on this issue guys, thank you in advance
Hi all, I have Avaya duplicated Definity System (MCC cabinet) running Avaya Communication Manager, ACM2.2.0 (R012i.02.0.111.4) that is showing mismatched software against SPE-standby (cabinet 1A) when “status system all” command is run and showing “No-License: Serial Number Mismatch,” “System...