  1. jon83

    SIP trunks on 3300 MX

    Hi I had a similar problem last week with Gamma with phones unable to transfer calls or hold and upgraded from 8 to 9 ur3 and problem fixed ! I was given advice from Gamma to upgrade.
  2. jon83

    3300 Analog Trunks not clearing down

    Here in the UK its the disconnect timer needs to be set higher than BT which i think is 180ms.
  3. jon83

    Rad recordings

    i have seen the rad files in there when you do a manual backup How To Manually Backup Voicemail On A Mitel 3300 Print View by: Chris McAndrew Total views: 67 Word Count: 707 Prior to this procedure, perform an ESM backup without saving voicemail messages. Procedure Summary A. To...
  4. jon83

    Mitel 3300's connect via SIP

    just use sip trunks on both sites
  5. jon83

    cant delete element opsman

    I have checked all the schedules and it's not in any?
  6. jon83

    cant delete element opsman

    Hi has anyone come across this problem when i try to remove a network element in opsman. I have followed the help guidelines. I get this message “The current entry is being referenced by another application. Please remove all references to this entry.” ??
  7. jon83

    SIP G729

    Hi how do you force SIP trunks on a 3300 to use only G729? I've placed the SIP peer in a different zone but calls still use G711.??? DO I need more DSP resources? I have an MXE with a dual DSP?
  8. jon83

    Wireless SIP Phone - Mitel 3300Mxe

    I know someone using a Ascom wifi phone and seems to work quite well. Ascom i75 is the model.
  9. jon83

    AT&T Answering Machine is not recorded

    is the wiring only using 1 pair. i had something like this with a fax the fax would answer but nothing happened, but when i made sure the lead it was using was only using 1 pair( i snipped the other wires). Then the fax worked! its a long shot and it may be related.
  10. jon83

    Networking between International sites

    I think there is port blocking going on. I got the IT bloke to do a trace on their routers and found some 3300s werent getting a reply on port 1067. thanks
  11. jon83

    add a static route to 3300

    hi is there any way to add a static route to the 3300. currently i have the layer 2 switch as the gateway for sip trunking. but now i need to connect another phone on a different network, so i need to add a route. Is there anyway to add a route to the layer 2 switch?
  12. jon83

    Networking between International sites

    Hi I have a customer who has sites in Australia, Malaysia, South Africa. I have setup clustering, the sites are getting out of service only for the sites in Malaysia and South Africa. The IT guy tells me there is no port blocking going on. But when I do a trace calls are not even hitting the...
  13. jon83

    SIP

    Hi I gotten faxes to work ok just set G711 only on PAP2T.Use Them all the time on remote sites as analog devices where there is only an network connection. Im not sure about the DECT does it have an R button?
  14. jon83

    SIP connections?

    I'm having a problem with sip trunking the 3300 seems to only allow calls through one sip trunk provider. i have programmed multiple sip providers for the customer because different companies use different trunks? I get failure when trying to use any other sip trunk than the one i first got a...
  15. jon83

    Re :3300 Mobile hotdesking

    check both extns are in directory assignment of each controller?. check logs on each controller to see what the error is?
  16. jon83

    SIP 2 SIP trunking?

    Thanks everybody I figured it out and it works! It was quite easy.
  17. jon83

    SIP 2 SIP trunking?

    It's what the salesman sold them now I need to Know if it will work?
  18. jon83

    SIP 2 SIP trunking?

    Hi can the Mitel do SIP to SIP trunking? If so is there a howto any where? I need to connect 2 3300's together. Thanks
  19. jon83

    SIP Device

    Hi I'm using Linksys PAP2T devices on a Mitel on a remote site with a VPN, 5212 are fine, but I'm getting call drop all the time on the analog phones. Has anybody else come across this problem? Or recommend a better SIP ata device? Jon
  20. jon83

    5550 ringing as huntgroup

    Hi Just in relation to your thread are the 5550s connected to different controllers?. If so how did you manage to get all the consoles to ring at the same time?