  1. locg

    Caller connect errors

    I'm the tech. I havent replaced any hardware yet causes i think the provlem is external im putting a battery backup/ups on it to see if that does anything.
  2. locg

    Caller connect errors

    I have a MICS R6 with pri and a nam r7. The customer says that sometimes they here the phone ringing in a strange fashion, then when they pick up nobody is there but caller keeps hearing it ring. this happens periodically on different DIDs. I tried making test calls myself if it worked each...
  3. locg

    Analogue Extension Module recall

    do you have allow link set to yes in set restrictions?
  4. locg

    four digit dial

    Thanks to touchtone tommy I Found a way to do it using a port for each ext,authorization codes and call forward
  5. locg

    four digit dial

    I'm working on a magix and I wanna create four digit dial between two sites.Ie. when someone presses 5*** the system dials a designated string of numbers with the wild cards at the end of the string.pauses might also be a factor. similar to destination codes on mics or remote call forward on a...
  6. locg

    Ghosts on Ext # 17

    I assume you've done this but have you reset the system reseat to the module
  7. locg

    Ext. 10 mailbox woes....

    is the schedule set to always in #507
  8. locg

    ip office training

    new york
  9. locg

    ip office training

    Does anyone know where I could go get training on ip office? I am even willing to pay someone to tag along on their next install.
  10. locg

    close business key?

    My customer told me the had a key that switched between the night and day greeting for a call center. what feature woud that be? F909? 7 .0 mics with 2.10 call pilot 100
  11. locg

    cant create mailbox 110-119 on call pilot!!!

    thank exsmogger. excellent info.
  12. locg

    cant create mailbox 110-119 on call pilot!!!

    For some reason I cant create any mail boxes in that dn range. Is this a bug or may I have to renumber something for it to work. help asap
  13. locg

    AOG00ENG and AOF01ENG

    AOG00ENG and AOF01ENG If anyone has these map files could you please email to john(at)acsnyc(dot)com Thanks John