Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: Webnx
  • Order by date
  1. Webnx

    IPO 400 issues with analog ports staying open after disconnect

    I was able to correct this today. I changed the port type to IVR and changed the "disconnect ??? " the option that pops up after you change the port to IRV to 32ms (the max) I found out later most devices need atleast 150ms, and the default time out is 10ms. btw 32ms = 320 ms, as...
  2. Webnx

    IPO 400 issues with analog ports staying open after disconnect

    we have IPO 400, our inbound lines come in on a t1. we have a 30 port digital add-on for most of our extensions, but we also have a 16 port analog box for our automated dispatch system. it has 6 analog lines in a hunt group. it works fine / answers and transfers calls fine. however we...
  3. Webnx

    Odd problem dialing out.

    Sounds like this is common. we are having the exact same problem, well both problems. the first one is people don't dial fast enough and it drops the call. that problem is a no brainer as the timeout is set to 4 seconds. now the real problem happens as random, but it happens alot. it...