Yes, all are in sync, have now been reset and upgraded to latest OS as well. The stack ran as configured for years so obviously something else has failed beyond the one swtich that has been replaced but I cannot seem to find the issue. I appreciate all comments. I think I am going to replace...
Thanks for the reply.
Yes, the base switch settings are good and have been double checked. The stack comes up without issues, identifies the base and works at first but then has the blinking stack configuration error later.
I've watched each switch to insure it selftests properly and none...
I have a stack of three switches (450-24T) in a closet that is suddenly having cascade issues. The base unit has a 400-2fx MDA module.
Here's the log from one of the units that seems to have started the issue. This unit is no longer in the stack but problems persist...