  1. pcasi

    35XX Series with VLAN tagging

    We are setting up the new 35XX phones on a 9.5.13 VCX system and using tagged VLAN for telephony but this feature seems to not be working. If we put a 31XX series telephone on the same port it does recognize the tagged vlan and works properly. Has anybody installed those phones on a similar...
  2. pcasi

    3Com NBX 6.5 released

    Just when i was thinking there would be no new developments for the NBX line i got this on my Inbox: 3Com® is pleased to announce the general availability of the 3Com NBX release 6.5. The 3Com NBX V5000, V3000A, V3000BRI, V3001A, V3001BRI and V3001R are all full-featured IP telephony solutions...
  3. pcasi

    NIF2 R11A

    Has anybody tried to update NIU2 firmware to R11A, i was sent 2 files, one labeled "nif2r11a" and one labeled "boot" but no instructions on wich file to upload. Should i upload both of them? If so in wich order? I appreciate your help. Regards, pcasi
  4. pcasi

    Mx-One TSW or TSE for USA

    Hi, we are a mexican company with a MD110 installed base and we are setting offices in the USA, we want to install TSW or TSE in those new offices, but i´d like to do some research before we decide the definitive solution. I´d be very grateful if any of you who work with Ericsson in the USA can...
  5. pcasi

    Can NBX use NTP?

    Hi, i´m fairly new to NBX and we are running a V3000 on 5_0_28 software but i´d like to know if it is possible for this system to obtain time from a NTP server? Or does it run a NTP server so other devices can obtain time from NBX? Thanks in advance, pcasi
  6. pcasi

    NIU2 doesn´t allow change of firmware

    Hi, everybody, do you have any idea why this NIU2 won´t let me change its firmware? Thanks in advance. <CNBLI:bpos=1-0-52,path=/sysn/usr1/ses/fw/nif2r4a.fw; CNBLI:BPOS=1-0-52,PATH=/SYSN/USR1/SES/FW/NIF2R4A.FW; SURE? (YES/NO) <Y; ORDERED <; SYNTAX ERROR <; SYNTAX ERROR SPONTANEOUS PRINTOUT...
  7. pcasi

    Write protection error and OPI issues - MX-One TSW SP2

    Hi Everybody i hope you all have a happy new year. Well, we´ve just upgraded from BC9 to MX-One and i spotted a couple of things that seem wrong. 1.- Alarm code 3 Level 1: with this description and signals: CLASS: 1 3 WRITE PROTECTION ERROR DATE TIME ALP NOIF UNIT EQU...
  8. pcasi

    DRG in BC11 SP15

    Hello everybody, we´re running BC11 SP15, currently we have several IP phones working with ELU32 along with analog and digital extensions, but we need fax over in the building where our IP extensions are located. I´ve been reading about the DRG solution but i think we need an ITG in order for...
  9. pcasi

    Redial when ECF

    Hi evrybody, we have this situation going on, it´s a MD110 BC11 SP14, an user has his extension forwarded to an external destination and can´t use the redial function (***), when he cancells the diversion the redial function works perfectly. Is this a normal sitation with Md110 or it´s a...
  10. pcasi

    NIU Debugger stata

    Hi everybody, I was playing with a NIU board and made a terrible mistake with a command (invalidnif), now this board is useless, but i found that if i connect a V24 to the third port there´s a NIU debugger running, so i was hoping maybe there´s a way to get this board back on normal function...