Hi guys.
Yeastar is connected with OS4000v8 via SIP trunk.
Whenever I call any Yeastar Subscriber from an external number I get a "+" sign before the number like this:
+000 450-27-20
I use this LODR
ADD-LODR:251,,,,ECHOALL;
ADD-LODR:251,,,,END;
ADD-LODR:251,,,"Yeastar";
I would be grateful...
Hi guys.
I have an OpenScape 4000 v10 which is connected via SIP trunk to Yeastar.
Trunk works without problems.
OpenScape side - 4XXX
Yeastar side - 1XXX
I need to add the 210 prefix to 4XXX when calling any Yeastar subscriber.
The only records I have are...
Hi guys. I need assistance in configuring Enterprise Gateway.
What I have for now.
Installed EcoServer with OS4K_V10_R0.28.0 as Enterprise Gateway.
AP370013 with installed LTUCR card.
What I can't understand how to connect it to the Main Openscape 4000 V10 as Enterprise Gateway.
Is Enterprise...
Hi guys.
My PBX is OpenScape 4000 v8.
Need help to delete BPOOL between STMI-X cards.
At the moment I have a pool between two STMI-X cards.
DISPLAY-BPOOL:MTYPE=CGW,POOLNO=2;
H500: AMO BPOOL STARTED
+------------------------------------------------------------------------------+
| POOLNO =...
Hi guys,
I need some subscribers to receive calls only within the country, whether it be a mobile or regular city PBX.
Is there a way to achieve this?
OpenScape 4000 v8.
Thanks in advance.
Hi guys.
I have a SIP-Q trunk between OS4K v8 and OSBX8 v3.
All calls from OSBX8 going through OS4K.
When I call any city or mobile number from any of the OSBX8 subscriber I get the same caller number which is our general number - 194807000.
I've already tried LATTR=PUBNUM in LDAT but it...
Hi.
OS 4K v8
Is it possible to set delay while dialing phone numbers in 4K?
The main purpose is to use 4 and 5 digit phone numbers even if they overlap.
For instance, 4343 and 43431 numbers.
Is it possible to set some delay after 4th digit to be able to wait for 5th digit?
In case of pause...
Hi.
I have a problem with connecting connecting OpenStage Key Module 15 to OpenStage 15T on HiPath 4000 V7.
I know that to connect BLF (Busy Lamp Field 40) you need to activate the setting in SBCSU command
CHANGE-SBCSU:STNO=XXX,OPT=OPTI,BLF=Y;
Then you just need to check it...
Hi guys.
I have HiPath/Unify 4K v8 with 4 digits interanl dial plan (XXXX).
Need to change dial plan from 4 (XXXX) digits to 5 (XXXXX). This is the main goal. Changing whole PBX to 5 digits is not possible now.
It is possible to use 4 and 5 digits dial plans at the same time if I have free...
Hi
I have more than usual call delay (about 6 seconds) between HiPath 3800 (latest version) and OSBX8 v2.
When I call from OSBX8 to HP3800 everything is good.
Analog Trunk is used to do calls.
Hi.
HiPath 3800, H3K_V9_R2.5.0_058
I have 3 numbers in the group: 2 HFAs and one SIP (SL450A).
Hotline number is 5.
When someone calls 5 and I pick up one of HFA's phone no missed calls on HFA but SIP has missed call.
When I pick up SIP no missed calls on all of the phones.
Does HiPath...
Hi guys,
have an issue with the license.
When using DISPLAY-CODEW:; command from Comwin I see proper information about license but Assistant shows me V7 (Grace Period).
The system is duplex but at the moment only one proccessor is working.
I had an issue with the station couple days ago...
Hi Guys.
Can you explain me how to configure trunk between OpenScape 4000 V8 and OSB X8.
OpenScape 4000 V8 has DIU-N2 board on 1-1-12 and OSB X8 has DIU-T2 on slot 10.
I've read alot of threads from this forum about creating trunks
https://www.tek-tips.com/viewthread.cfm?qid=1740928...
Hi guys.
There is a certain procedure how to enable Signaling and Payload Encryption (SPE) on OSB X8.
I did exactly as the manual said and it worked.
After that I did Factory Reset the station and now I cannot make it work again.
Maybe someone faced the same problem.
OSB X8 V2 R7.0.0 871
Hi guys,
I have an issue with OSB X8 v2.
Here is the part of evtlog.log file.
I get a lot of "!Poolerror" after that OSB X8 v2 goes to restart.
I've already changed the firmware to R6.2.0_029 (which is the last at the moment) with no results.
What do I need to check first?
Thanks.
...
Hi guys,
have an issue with OpenScape 4000 v8 Duplex.
I have no problem with the Active, but Standby goes to resatrt 10-15 times a day.
When restart occurs this errors appears
F4057 M8 N1741 NO ACT BPA CP DBAR 19-09-19 20:09:25
ALARM CLASS:CENTRAL:023...
Hi everyone.
I have two HiPath 3800 connected via STMI2 with 8-port switch with common network cable.
HiPath 3800 have the same softwrae version. STMI2 have the same software version.
I've already configured trunk between HiPath 3800.
Everything is working but LED signaling between HiPath...