Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: Terry6868
  • Content: Threads
  • Order by date
  1. Terry6868

    Avaya Aura Add second line to SIP Viper

    Good Day, Has anyone done or was tasked to add a second line to a SIP Viper phone if so what option/feature would that be associated with. I know MDA allows you to register an extension on multiple devices but I would like to add an extension to a SIP viper device if possible. A Viper phone...
  2. Terry6868

    Can't dial new DN range from another site

    Good day, I am programming new phones with a new DN range and internally I can dial the new number range but, one of my sites are getting a fast busy when they try to dial the new number range. The DSC for the new number range on the remote site is pointed at the VTRK connecting the two sites...
  3. Terry6868

    DTA errors

    I would like to know is there anything I can do or is it my telco provider issue. I am getting DTA203 0 0, 1, 2 DTA201 0 0, 1, 2 DTA204 0 0, 1, 2 errors I am thinking it is a far end alignment issue in LD 60 when I do a lcnt the RAI counter was over 2,000 on each one of these loops which I...
  4. Terry6868

    Call Pilot Issue

    Good Day has anyone ran into an issue where your two DNs associated with the operators go straight to voicemail instead of ringing out if you call them directly. They are idle and you can make calls from them MSB is not enabled or call forwarding.
  5. Terry6868

    PDT session only when using putty

    Good day gentlemen have any of you ran into the issue of PDT login when using RLOGIN via putty and seeing SL1input not defined.... I can't exit out of PDT (using: sl1input) and get back to the CS login screen. When I try to login I'm always taken to PDT prompt and can't exit out. When I login...
  6. Terry6868

    Datapulse Intuition 1000 console ODBC issue

    Hello, I have 5 operator consoles and one is not sharing the updates of the ODBC. When the other 4 consoles add a new user the change is saw instantly. The one that is not working doesn't show the folders or the people added by the other consoles. I have checked the ---> Open Data Sources...
  7. Terry6868

    Corporate Directory CS1000 7.5 Issue

    Does anyone know what could be a possible issue is to why my corporate directory on the phone shows "Directory Unavailable" In the UCM subscribers are there I went to the corporate directory table configured and ran report next logged into the CS1000 went to the PDT level found my CpDir0.csv...