Hi,
we configured new Mitel 3300 AX controller.
We are programmed SIP trunk between Siemens Hipath 3800 And X-8 with Mitel AX controller.
When we received incoming call on SIP trunk from other Siemens location to Mitel AX controller its working fine.
While we dial other location from AX...
Hi
I am using Mitel Mivoice 400 and 8DSI card and 8 FXO for Analog trunk.
Customer having Hotlines using for Point to point connection.
I am assign KT line key for each hotline on 5360 digital phone.
Now i am using issue,One way speech when i dial from by pressing any KT line key.
When i...
Hi,
I am configuring mivoice 400 and created time controll function for reception.
for switch 1 *85021 for day
For switch 2 *85022 for Night
Manually working fine but automatically its not routed.
Please suggest me any setting for automatic time control routing.
Hi
I am configured SIP trunk on Mitel A 470 with other location through MPLS link.
Now there is one way speech at other end,there are not able to heard our voice.
from analog extension call get connected and both the end speech is ok.
please let me know any port required to open on RTP on...
Dear All,
i am installing Mitel A 470 with version 5.0 HF 4,i am using Analog trunk in system.
I am able to initiate internal conference 1+5 on both Analog and SIP extension,while i am connecting external party conference not initiate.(suppose dial any number and put on hold then i connected...
Hi,
I am trying to connect mitel A 400 system to Hyper terminal for call charges RAW data.
While i connect to hyperterminal to Mitel controller its show connection refused .
I am trying another tool Tterm pro and By putty,its same thing happened connection refused.
Please suggest me setting...
Hi
We are configured 2 mitel mivoice office 400 system
System A Having Public PRI trunk
System B interconnected with System A with private SIP trunking
System B access outdial from using System A PRI line
In System A there is MSN Series is 2300-2499 ( PRI having 300 MSN)
system A Extn...
I am facing problem,when i restart Master system that Satelite is frequently restarted and its take 4 to 5 hours to stable.
Error log attched.
Please give me solution for the same...
Hi
We are facing disturbance issue while calling in betwwen Master to Satellite system.once in ten calls.Is it Network issue or Resources issue,
Please help me out.
Thanks & Regards
Hi
We are interconnected Mx One and Mitel A470 with SIP trunk,while PRI trunk in Mx one,In Mitel A 470 we ceased PRI trunk via dial '0'
and external number.
Call initiared and speech established,but their is no public dial tone while we pressing '0'in A 470.
in A 470 we are creating PISN user...
Hi,
I am facing problem in 5380 ip phone its showing system overload in Mitel A 470 system.Media resources is unable.
No call from IP to Analog,while we dial from IP to Analog is showing "System Overload"
Please suggest me any corrective action to resolve the same.
Thanks
please share me dial plan for Polycom Trio 8800 in Mitel A 470
existing dial plan is
[2-9]11|0T|011xxx.T|[0-1][2-9]xxxxxxxxx|[2-9]xxxxxxxxx|[2-9]xxxT|**x.T|+x.T
its very urgent i am stuck in installation.
please help me out,
Dear all,
I am facing problem in Mitel A 470 System configuring with 196 analog extension and one 5380ip phone,connected auxiliary power supply.
temperature of card is showing abnormal screen shot attached.
suggest me its need to connected secondary fan...
Dear
I am facing problem with Mitel A 470,when i transfer call to A to B by pressing flash key in Analog extension.while once i press the flash key call on hold but suppose i need to take call back that time i need to press flash key multiple time.
Also if i kept my phone on hook after pressing...
we are installing mitel A 470 in Hotel,customer required single digit extension number for there room service and other facility.
but there is number conflict like they need 4 number for room servece and room extension started from 400....450
is it possible without number conflict in...