I have all the necessary hardware (2GB RAM---40GB HD)
Confused as to the install process.
Do I need both the 7.5 Linux and the 7.5 CS Install RMD's?
My thoughts were to install the 7.5 Linux and then add CS (keycodes) through UCM but not sure.
Also do I need FMD on the CPPM in addition to the HD...
Is there any way to identify the part # of the power card in 11C?
Have tried inv generate/ inv prt in LD 117 with no results.
Any one know of another way to get this info?
Thank you
I'm new to Samsung.
Trying to backup VM and keep getting "Failed to connect to FTP server".
Have done this successfully on OS7100 but having this issue on 7030.
Thanks for your help.
I have been unable to locate a list of memory size for the different nomenclature's on the CPDC and CPMG cards.
They both have AA,AB,BA,BB version's but like I said, I cannot locate the difference in memory size between the different version's.
Any help is appreciated and thank you.
Is there any way to assign the TLAN IP address to the daughterboard through CLI?
Normally this is done through UCM/Element Manager but I cannot access (long story).
Running 7.5 and looking to assign TLAN IP to 2 -NTDW64 DB's on NTDW20-MGX card.
Thank you
Installing a 7.5 (SA) CPPM in DU14 chassis.
Can we make the 1 CPPM card the UCM, CS and Sig server? (We have MGC card as well).
If so is all programming done after installing Linux on CPPM and then adding Call Server/key codes through UCM?
Do we need CPDC card?
Thanks
Getting these errors;
On Main Board-interrupt error: MGX Cardlan access is seized by other side 1
On Daughter board- The card lan is seized forcibly
These errors occur after a successful upgrade.
I've swapped out FMD's and the errors still occur after upgrade.
I'm guessing hardware but don't...
I'm trying to restore a backup via USB and just can't seem to find the proper prompt in Linux.
My access to UCM is not working currently (long story) so I need to do this through Linux (CLI).
Any help is appreciated.
Thanks
Very new to Avaya system.
I have a G250 that I can access through S8300 Site Administration.
I would like to program the 4 trunk ports and assign them to a set.
Can someone please provide the prompts necessary.
Thank you
Rls 5.5....CP-PIV
Cannot SCPU.
When I Stat CPU they read redundant and health is the same but the IPL health is 2 on Core 0 and 0 on Core 1.
This is the message I get "local ELAN health is better than remote."
I have researched IPL and come up with nothing.
Any assistance is appreciated.
Thanks