  1. JMarine0811

    CISCO VG450 Factory reset

    Has anyone done a factory reset on one of these? If so how? Through command line. I cannot seem to find instructions anywhere. Brand new hardware, I messed up in a couple of settings, just feel like I want to wipe it and start from scratch. It will be a learning process as I have used...
  2. JMarine0811

    Mitel SX2000 Card Swaps

    Unfortunately, after almost 25 years of faithful service, we are switching our hotel analog phone system from the Mitel SX2000 to a Cisco VG450. Mitel SX2000, 16 rooms per card and reflects that in the punches on the blocks and Amphenol cables... we have the female/male adapters for the...
  3. JMarine0811

    Mitel SX2000 --> Cisco VG450

    After almost a quarter century, our company is moving to Cisco VG450 for analog lines in our hotels. Not a project to which I am looking forward. I have a question about changing out some cards in the SX2000. Cisco has the ability to use 24 pins in the Amphenol cables while Mitel utilizes...
  4. JMarine0811

    Error on 3300 MXeIII

    0x453cec0 (tNetTask): arptnew failed on 0 Has anyone ever seen this? If so, could you please tell me what it is? I'm looking for it online and in the books but I cannot seem to find anything on it at the moment. Release 7.0 software load 13.0..28 It is connected to the SX2000 light. Thanks!!
  5. JMarine0811

    ASU II, Amphenol, Block...

    Mitel 3300 MXeIII v. 14.0.0.97 ASU II, 24 port ONS x2 T1 Smart Jacks for LD and Local Client required move from "phone room" that was occupied by systems for over 20 years, to new data center. T1 for local and LD. Successful move to new location. New Smart Jacks and cable ran about a year...
  6. JMarine0811

    Local/Toll Free "Access Denied"

    This is a weird one. I have not seen this problem before except for this client about 2 months ago. Maybe someone has encountered it here... The following has been an issue with this client... Mitel Version 14.0.0.97 Dual T1/E1 Framer This was not an issue prior to changing out to a T1/E1...
  7. JMarine0811

    Access Denied BUT....

    Hello all. Mitel 3300 MXeIII version 13.0.1.28. Installed a T1/E1 card about a month ago because the old NSUII finally died at that time. THE ISSUE IS... When dialing Local and 800 numbers, phones get access denied. Try a second time immediately after by either manually dialing or pressing...
  8. JMarine0811

    Moving 5550...Upgrade on controller

    Hello, It's been awhile. "Controller 1" is being upgraded to version 14.0.0.97. It is in a cluster with a few other controllers at various locations. There are three 5550 Consoles and they are not compatible with this version unless licenses of some type are purchased. Apparently expensive...
  9. JMarine0811

    ibutton

    About 9 years ago, a couple of people that were taking care of the Mitel 3300 at one of the locations, lost an ibutton to the "resilient box". (MXe machines) This particular operation is 24 hours and should see little if ANY downtime. They have purchased a virtual license, I will be setting...
  10. JMarine0811

    What is this?

    Mitel 3300 MXe III ver. 13.0.1.28 MIFSM... I get these warnings once in awhile... Could someone explain what this is please? Thank you. 4164 Date 2016/May/18 Time 08:51:42 Source MIFSM Description Unexpected ResultHandleEvent() - No transition from (MiFsmState CONNECTED) on event...
  11. JMarine0811

    APPSL - ATA .....?

    I attached a screen capture. This one is new for me. Mitel 3300 MXeIII v. 13.0.1.28 I was told that this just started happening around 0700 this morning. Page 198 and 199 shows... 2381 2016/Jan/26 07:58:21 SAC SacSendCallInfoChange->msgQSend CALL_INFO_CHANGE FAILED for DevIndex 161...
  12. JMarine0811

    CEID Index...Error

    CEID index being changed is used in Remote Directory Assignment Form." This error comes up when I attempt to delete an old and defunct MXe 3300 (OLD) that is no longer in our cluster. However, it only appears on one controller (POW) out of the 15 on this particular cluster. Quick history...
  13. JMarine0811

    Headset for 5330

    Just a quick temporary fix. One guy here has broken his wireless Mitel headset 3 times in the past year. Going to be charging him. Instead of getting this dude another approx. $250.00 headset that he can't seem to take care of, what would anyone here suggest as a descent substitute that...
  14. JMarine0811

    Blank Alarm Group Summary

    I am working with a 3300 MXeIII, version 13.x.x.x. There are at least 20 machines at different location in the network/cluster that this system is part of. On all of the others, I go to Alarm Group Summary and I see all of them to get the basic information as usual. This particular machine, I...
  15. JMarine0811

    remote restore..reboot.

    Mitel 3300 MXe version 13.x.x.x remote system restore. After loading it requires manual reboot. I have never done so remotely. Reset system, reset call server or reboot apc... Which is suggested? Have to do this about 02 or 0300... In a few hours. 😊 Thanks in advance.
  16. JMarine0811

    Upgrade Question

    Tonight I will be upgrading a 3300 MXe ver. 10.2.0.26_2 to the current 13.xxx. This particular system is for a hotel and is tied in with some SX2000 per-nodes. Eventually this will be switched out to some ASUII's or whatever is decided upon, but this is what I have to work with for now...
  17. JMarine0811

    Subnet ?

    Mitel 3300 MXe III, 13.0.XXX installed. Working perfectly with all systems in our clusters, HOWEVER... (here it comes) I noticed that I either fat fingered or just forgot to go with fffffc00 (255.255.252.00) for my subnet... instead I just went with ffffff00(255.255.255.00) when I set this up...
  18. JMarine0811

    RS232 port and Emulators

    Working on old HP laptop to setup 3300 MXE's and MXEIII before taking it into the field. We were not approved new laptops through the company...my usual Windows XP, with all of my Mitel stuff had a hard drive crash. Could not recover it. Might have to get an image from someone higher up in...
  19. JMarine0811

    Hello All

    Hello everyone, I have been a member here for awhile and decided to finally post something. I have gained some valuable information here that has proven very helpful. Thank you all for the input of knowledge some of you offer. I have come across some good solutions on a few things through the...