I am trying to logon to Aastra Bms configurations;im getting cannot connect to the system[10986] Could not get I/O for the connection to the agent host 127.0.0.1(invalid port 7777?).Please help
Thanks
vhttps://res.cloudinary.com/engineering-com/raw/upload/v1441883771/tips/Aastra.jpg_lyfdqk.docx
We have BP250 pabx system and we are unable logon to the system.We are unable to get the installer.Is there anyway to override the password for the system?
Thank you in advance
I want to add Card and activate in a magazine (006-1-62).It shows passive
Please help
CNLIP:LIM=6,DEV=YES;
LIM CONFIGURATION
LIM NUMBER 6
LIM CONTROL LIM CONTROL NUMBER OF SERVICE
SYSTEM SIDE SYSTEM STATE PCM-LINKS STATE LIM
A EXECUTING 1...
We have problem with one of our Lim 5 which does not contact.Tried to restart the said lim with no success.This happened after power outage and the PU5DC was burnt and we exchanged the card.Please help.This are alarms
ALLOP;
ALARM LOG
IDENTITY: JUS-BC9B-CNI84
VERSION: LZY2035143/1/R1A
DATE...
For over 1000 extensions(DDI numbers) we have got common number as CLI,for example if anybody makes a outgoing call from any department the CLI number is the same.Can you please help so that we can setup CLI for every DDI number.Thanks in advance
We used to pickup calls for groups using common number 2 and now after reloading the system we cannot pickup though we can set Call pickup groups.How can we assign a common call number(same number as before) for call pickup group?
Thanks
We used to pickup calls for groups using common number 2 and now after reloading the system we cannot pickup though we can set Call pickup groups.How can we assign a common call number(same number as before) for call pickup group?
Thanks
After power outage one lim was off and we encountered the cuttinng of calls during conversation(on all lims).We restarted the system and it came up.When we do the dumping the system shows that I/O device board blocked.
ALLOP shows
FAULTY IPU BOARD OR CONNECTED I/O DEVICE
BUFFER TRANSFER HAS...
Almost after everypower outage the system(MD110) needs to be resetted.I would like to know which device on the Lim to reset.I know that we check the power and rectifier.I just wanna know which connected card.
Thanks
Our system(Md 110) goes off when there is power outage and this makes REL2 to be invalid and updated information tend to revert back.My question is do we have to purchase/replace the power supply for md110 or is there any explanation for this problem
Thanks in advance
since power outage,i have problem that the changed data om md110 reverted back.
dubdp:
REL1 REL2
23:00 03 June 13 Not valid
Divergent Time and Date
Lim 1 23:00 03 June 13...
I am not much familiar with md110 and i need help regarding operators.we have got about five operators and they have to be configured to category that enable them to receive calls and not call outside and also enable them to call to extensions.