I have a Hipath 4K V8.
Found this today: OPTIMIZE-CLIMA
I can't find any documentation on it.
What does it do?
When I list my CLIMA lists, the CLIDPNO slots are out of order. Does this line them up correctly?
Thanks.
I've been asked if there was any way for a user to block an internal or external call from showing up on call logging.
I know there is a feature code to block CID output for one call, but it still shows on the call logger.
Thanks. HiPath4K v8 here.
I've got a Hipath 4kV8. I'm at R1.19.3. I was shown a long time back how to set the IP address for the NTP server in YAST, but, if I remember right, that's not the place to set it anymore.
For the life of me I can't find where to set it now. I didn't find anything in the Wiki.
What am I missing...
I was finally able to update my system from V6 to V8. My TSDM software is finally working, but it seems to have issues. The most annoying thing at this point is that after a software update on my 40Ts, several say "NeedToReboot" for their status.
I have rebooted the PEN, and I have rebooted...
I've got something weird. On my HP4K V6, one of my extensions is now only ringing twice before going to xpressions. All other extensions ring 4 times before to xpressions. This just happened recently. I haven't made any setting changes. Global time is set for 4 rings. I thought that individual...
I've got a problem. I have Openstage 40T (TDM) phones that are losing their display to the tune of 1-2/week. The display goes blank. Attempting to change the contrast has no effect. Putting the phones on a different port/STN has no effect. This just started 2 months ago. No other problems with...
thread965-1617426
The question I have was brought up in an earlier thread, but look like it didn't get resolved.
I have a Siemens Hipath 4K V6. A user today asked why the Polycom Soundstation 2 in the conference room couldn't set up a conference call. It's a feature of the Polycom apparently.
I...
I'm trying to build a new DNIT for a number that needs to be redirected. I want it so that when 85 is dialed, it dials 5085 instead. I haven't tried building one before, so I'm missing something. 78 is in use already converting from 78 to 834. When I regened DNIT and tried to add 85 using the...
This showed up ~three weeks ago. I thought maybe that the system was installed with only a two year license. However, the system was installed 3/26/12, and it shows the license expiring 5/16/14, which equals 781 days. (2 years = 730 days.)
One of the DSCXL2 boards was replaced about a month...
Has anyone ever heard of a PEN power toggling?
When I logged off a STNO, and tried logging on another, the 40T wouldn't accept the new number. Instead, it stayed at "device relocating". COMWIN shows the STNO assigned to the PEN.
I watched it for a bit, and saw it power off and back on it's own...
I have an analog phone on my HP4Kv6 that has power, but no dialtone. In the system, it shows status as READY/CP. I've looked through the books, but haven't found that one. What does it mean? Thanks!
Since the install of the Openstage 40T phones here, several users have asked for which headsets to use on these phones, as the old ones don't work.
With my old system, Plantronics Telephone Headset System S12s were used. It connected between the phone and handset.
The Siemens sales rep swore...
I've just jumped from an ancient ROLM 9751 to a Siemens HiPath 4000 V6! Went to the basics class, but had to leave early due to an emergency. The class only covered the V5 though (so nothing on the completely different V6 hardware). I'm trying to figure out this system.
I have no documentation...