  1. jherrick

    Fdms cardnet micros3700

    Looking for a freelancer to convert to fdms/cardnet north direct driver to a micros 3700 v5.7+ Let me know if interested.
  2. jherrick

    MICROS 3700 5.7.5 RVC Change

    Hello, Im attempting to use Change RVC No Signout to put the manager in the right RVC and then provide the correct screen for that revenue center. However using the built in function if the manager is currently in that RVC it just gives a message saying "Already in this Revenue Center". It...
  3. jherrick

    Wiring diagram for WS6 com port adapter

    After making a couple of these adapters using oracles pinout provided in their documentation, I couldnt get them to work. So I tracked down a factory one to get the actual pinout. So here is the one I got to work. WS6 rj-45 to db25 serial https://www.amazon.com/gp/product/B007FZUEKO 1 3...
  4. jherrick

    res 3700 users

    so is everyone pretty much on res 5.7.5 at this point?
  5. jherrick

    WS5A Q2012F BIOS

    Thought I would throw this on here if anyone is interested. Its the final (I believe) BIOS release for MICROS WS5a. In order to boot to DOS from a USB to flash it, I had to remove the UDOC. https://drive.google.com/drive/folders/1oxfH_L6wJJQLBvEraFa0bwLwn9PtNEEc?usp=sharing Enjoy!
  6. jherrick

    pcwsapi.sys install on PCWS 2015

    Could someone please explain the correct way to install the pcwsapi driver to a MICROS PCWS 2015? I have version 6.0.0.1 of the driver. Thanks
  7. jherrick

    MICROS RES 3700 Employee Class or Job Code Print on kitchen chit header

    Is there a way to print the Employee Class or Job Code onto the kitchen chit header. I have searched for quite a while, and I feel like the only way to do this is to write a SIM that calls a custom DLL to pull the info from the micros database using the @CKEMP variable as the key so I can...
  8. jherrick

    MICROS 3700 5.2 Server on two subnets

    We have two network cards in our MICROS Server. One of the networks is an isolated micros network running on its own subnet. The other is our private work network running on a different subnet than the micros network. Is it possible to get POS configurator/Autoseq & Reports to run on...