So the current config is a universal trunk in the CS1000 to a standard 600ohm input. Not sure of the amp brand, but it is an audio amp, ie. Yamaha. Signal is then sent, amplified to speakers. Trying to get an FXO port to work with the same downstream set up. I can dial the route pattern, FXO...
Built a vpim entry and pointed it to our smtp server. When I compose the message and try to send it I get a message stating that the mwessage was marked private and cannot be sent. Tried marking it something other than private before sending it and get the same result. If I don't relay...
Who knows how to eliminate the two second delay when paging from an analog port. I'm sure you see in the subject that I'm connecting to a valcom unit. I have adjusted the eod timer for the paging route down. I think that it is just the nature of analog.