Hello all,
Is there a limit to the amount of remote shelves that a CS1K can have hanging off of it? I currently have two remotes and 5 shelves in the PBX itself.
Thanks,
Nick
Hello,
i read this thread and just wanted to clear up: http://www.tek-tips.com/viewthread.cfm?qid=1494799
so every TN must individualy be cls: cfxd and cfw 4?
thanks
i was instructed to take away the ability to forward calls off site, or off-net. I tried changing my line from cfxa to cfxd and it still lets me off-net to my cell phone. What am i missing?
Thanks,
Nick
Hi all,
Having an outbound source problem with caller-id on one of my T-1s (loop 3). The same DN (315-243-2332) shows up at a given distant end. I imagine it is a setting in one of the LDs but not sure where. Any help would be greatly appreciated.
Thanks!
Nick
Every week or two i have to go into LD 2 and set time and date (STAD) because the display time falls back five to ten minutes. Is there a battery in one of the cards that is dying or somthing?
Thanks,
Nick
Can anyone help me out here, like you guys always do. How can I find the serial number of the PBX? Is that something that would only be in paperwork or is there a way to check it in the terminal manager? May have been a stupid question. Thanks,
Nick
lONG DISTANCE loop (loop 2) is down. Provider came and stated it is on my end.
LD 60
.stat
DTI TRK LOOP 2 - ENLB
FFMT/LCMT/YALMT: D3/AMI/DG2
SERVICE RESTORE: NO
YEL ALM PROCESS: YES
ALM STATUS: RED YELLOW
CH 01 - DSBL TIE 3VCE
CH 24 - DSBL TIE 3VCE
Not quite sure what i should do next...
I have a group of numbers:
LD 20
REQ PRT
TYPE GRP
CUST 0
GRNO 10
GRPF 2337101
STOR 00 2337311
STOR 01 2337302
STOR 02 2337304
STOR 03 2337313
STOR 04 2337338
STOR 05 2337303
STOR 06 2337306
STOR 07 2337554
STOR 08 2337312
STOR 09 2337314
I need to add one or two more numbers to this group, is...
Im trying to stop the switch from changing the date on its own. Every time daylight savings arrives, I go into LD 2 to STAD, and a week later it automatically changes again. Perhaps a ghost?
Nick
Sorry, somehow this thread got closed..
i did switch it to a DN outside the DID range, i try calling from my cell phone and i get an out of service announcement, which is great. But for some reason when i dial 99 from my desk phone and the number i connect.
is there any way that a key on a 3903 can be disabled? i.e. made so that they key still appears, recives caller id, but can not go off hook?
thanks, nick
Hello all,
Is it possible to have a dn appear on a key (i.e. key 02)? Long story but it comes down to a caller ID issue; I want the CID to show up on the 3903, but make the customer answer the analog phone beside it.
Thanks,
Nick
I recently upgraded to a CS1000, i know in LD 20 you can IDU a digital tn, is there a similar command like that for these VOiP computer .com telephones? Sorry for the sarcasm, I'm an old school wire dawg. Thanks in advance!
Nick
I cannot PRT, OUT or ADD a certain exchange in ld 90. It gives me errors either ESM072 or ESM072.
Normally if an exchange isnt loaded in the PBX when i dial, it gives a fast busy. This particular exchange (956) is wierd because it lets me dial the whole number, but i get **your call has not...
Good Morning,
I am the main switch tech for my company and we are upgrading from an Option 61C to a CS1000. Just wondering if anyone else has experianced this cut over and tell my what I can expect i.e.
Are m2000 and m3000 series digital phones compatible?
If i am using the existing...
Hello,
Got a 61C, and at least once a week 3 of the same isdn lines go to release. this is what i get when i am notified they are inoperable:
LD 32
REQ: STAT 24 0 15
SW DSL L2 #TEI L1
== == == == ==
00 = IDLE LINE RLS 0 UP
01 = IDLE...