Hi, everybody.
I need some help from you. I have a central md110 erickson, I don´t know much about it. However, I am confused, some extensions goes to busy tone and I put the command:
<SUSIP:DIR=514;
STATUS INFORMATION AT 00:00:00 01JAN00
DIR TYPE TRAFFIC STATE/PTR LINE STATE/PTR DIV...
Hi, everybody
I need help for this issue, I have some alarms, that I don´t know how to interpret, but my telephony system goes down and some phones run out of tone for a while, then the phones have tone again.
These are the alarms: CODE 283, CODE 100 AND CODE 38
<ALLOP:CODE=283;
ALARM LOG...
Hi, everybody
I have this extension
<SUSIP:DIR=513;
STATUS INFORMATION AT 00:00:00 01JAN00
DIR TYPE TRAFFIC STATE/PTR LINE STATE/PTR DIV STATE ADD INFO
513 ATS LINE LOCK #021F LINE LOCK #0386
END
The line is locked. I already have restarted the board, I have...
Hi, everyone
I need some help here, I don´t have expertice in MD110 PBX, but I have an issue that is some analogs telephone work fine, they receive calls ok, but at the moment for doing a call, the phone is busy, so I can´t do anything. I checked the board with WINFIOL, and I restarted and it...
Hi everyone, I have a question I formatted my computer recently, before i could access to the MD110 via telnet and now i cannot.I can do ping to the NIU board, but in the software, the next message is shown "Error: Cannot get host entry" and other thing that i see is in the bottom says: Port...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.