  1. coameno

    I2002 phone will not keep its set ringer volume

    Have a switch with Sucession 3.0 software with two I2002 phase 2 phones that will not keep its volume. Have the latest Firmware loaded.
  2. coameno

    2002 phase I and II, set getting delayed dial tone and getting Handfree on its own

    I have a Nortel 3.0 relase 1000S system that I am having problems with the i2002 phase I&II phones, after a while the set goes on speaker phone on its own and when you hit the key to access the line the dial tone is delayed. Any sugguestions?
  3. coameno

    Keep Getting AUD093 errors on 5.0 WATV system on CS1000E CPPM

    Anyone knows how to stop these errors. The p25166.patch is loaded. Any help on this. These are my errors AUD093 00000875 0000084F 0F012674 00000001 00000000 % % AUD422 0EF53B80 00000407 00000003 00001244 00000001 0000124C 00000000 4042116 NULL % % AUD093 00000875 0000084F 0F012674 00000001...
  4. coameno

    How to RESET the Root password for UCM,

    I cant log into the UCM CLI as root account, states that the password is incorrect. How can you reset this password. This is 5.0 revised as 6.0 to meet JITCs requirements
  5. coameno

    Keep Getting AUD093 errors on 5.0 WATV system on CS1000E CPPM

    Anyone knows how to stop these errors. The p25166.patch is loaded. Any help on this.
  6. coameno

    How to RESET the Root password for UCM,

    I cant log into the UCM CLI as root account, states that the password is incorrect. How can you reset this password. This is 5.0 revised as 6.0 to meet JITCs requirements
  7. coameno

    NWS211 24 0 1

    I have a CS1000E system that during the midnight routines it keeps giving me the NWS211 24 0 1. The shelfs are working fine, how do I clear these errors. Thanks.
  8. coameno

    Paging system issue

    I have a CS1000E and created a paging port on the Universal Trunk Card. The customer has a paging system that needs a open close contact to activate it. Is there a solution to create this contact with another piece of equipment?
  9. coameno

    Analog ports having issues with Alarm CS1000E 5.0

    We just upgraded a 61c to 1000E 5.0 WATV and we are having an issue where a alarm that dials out on a 500 port on the switch to another device is not sending the correct data information. The set was configured like the old switch and worked fine. Is there something in the route I can turn on or...
  10. coameno

    ECM 5.0 Terminal Session wont Work

    I have an ECM 5.0 and when I create a terminal session via mgc or sig server or call server I get the java loaded but when I hit connect it won't work. Is there another way to get to the tty command line secure other than the tty ports?
  11. coameno

    CallPilot 4.0, getting no speech on RNA from on DSN calls

    I have a CS1000E with DSN 5.0WATV software and CallPilot 4.0. When we get a incoming DSN call if no answer it rolls to VOicemail but get no speech path. I check the channels and they are all doing the same thing. If you call internally the call rolls to voicemail and works fine. Only the DSN...
  12. coameno

    Can't open Callpilot Mgr on Call pilot web server after SP2 update

    I have a Callpilot 4.0 Web server that after adding SP2 I am getting a http error 401.1 Unauthorized Access on the web browser .Any sugguestons to fix this?
  13. coameno

    Emergency Login mode on UCM 6.0

    I am working on a CS1000E co-res system. Currently the log in is locked out. No matter what password you use it will give you a 428 error. If you re-boot the system it allows you to log in one time in the emergency mode. If you log out it locks out he terminal. I registers the MGC's with load...
  14. coameno

    CS1000E 6.0 EXit from CSLOGIN

    Besides the Control A D is there any other way to exit the CSLOGIN back to the LINUX command line. I tried the Control A&D and it is not working. I have a CORES system 6.0. CPPM card.
  15. coameno

    Error Code: SCH3942, on CS1000E 7.5 Adding sets on 16-35.

    When adding units on CS1000e 7.5, Trying to program units on a MGATE card LCSU, when I get to unit 16 I get Error Code: SCH3942 Error Message: For Touchphone and M2000 series digital sets, this feature cannot be defined for this key number (17-35). Severity: Info. this error. Any Sugguestions? I...
  16. coameno

    Database conversion from cpp4 to cppm 7.5

    I have a release 4.5 cpp4 that I am upgrading to 7.5. Is there an quicker way to merge the data to new system.\?
  17. coameno

    BOGEN PCM200C PAGING SYSTEM ON CS1000E 5.0

    I have a CS1000E 5.0 and programmed a WATS port for paging BOGEN PCM200C and it access the port but when you enter any key after the beeps it disconnects the trunk. It worked as a wats on a option11C,any sugguestions?
  18. coameno

    PROGRAMMING OF PCM200C PAGING SYTEM ON CS1000E 5.0

    I HAVE A BOGEN PCM200C PAGING SYSTEM THAT WAS OPERATING ON A OPT11C PROGRAMMED AS A WATS TRUNK AND WORKED FINE, THEY UPGRADED THIER SYSTEM TO CS1000E 5.0 AND WHEN YOU ACCESS THE PAGE PORT IT BEEPS TWICE FROM THE PAGING SYSTEM AS NORMAL BUT WHEN YOU DIAL ANY OTHER DIGITS AFTER THE BEEP THE TRUNK...
  19. coameno

    Reset nnadmin password on BCM 50 2.5

    I have a BCM 50 that no one seems to know the nnadmin password. Does anyone know how to reset it?
  20. coameno

    Menu password on IP Sets 1140

    Where can you globally change the IP SET Menu password? Can you include it on the DHCP string? Can it be configured via Element MGR? Or where.