please advise how to bar out going facility even internal dialing also for the phone in nec ips 2000 as we want to provide one internal phone at security office exclusively for incoming purpose.. they may be not able to make any internal call from that phone... please help us
regards
sampath
Dear all
we are using nec ips 2000 system. one particular internal phone is not properly ringing getting break ringing.the other all phones are ringing well as normal.. we have changed the instruments and tested... but this particular analog phone is getting break ring... please advise
thanks...
Dear sir
please advise how to make one group for 4 internal nos. as emergency purpose.
further please also advise us that we have one console which is being operated by nec ips 2000... how the operator has to intercept the phones when busy when there are urgent and emergency calls lands on...
Dear sir
We are using NEC ips 2000 with PRI (30 Juntion lines) when we are dialing... the only one number that is the first number in PRI is being displayed where as other junction numbers in PRI are not displayed in clip...Any one may please be given suggestion
regards
Dear all
We are using neax ips2000 system. some times we often found that some of the extension phones are dead having no dial tone. if we give ring to that particulars phones from other phone ..they use to get the ring and works as like as normal phones and there may not be any problem for...
Dear all
I would like to inform you that i want to do PHd on "Speech recognition techniques and their applications"
could you please inform me the latest topic on this subject please as for application submission is getting very nearer.. kindly help me in this regard
sampath
Dear all
As we are using ips 2000 system.. i wud like to know about the call park system and how to do that in mat worx32.. could any one pleae be explained in detail..and the detailed programme in mat ..
thanks and regards
ssk
dear all
we are using ips 2000 system in which we have configured three station numbers as emergency need under the code 99. now we want to change the station numbers under this code..
pl help us how to do that.
thanks inadvance
hi all
we are using ips 2000 and having only one ISTD faility junction among 8 junction lines.. when the station is called the operator for international call... how can we get selected the ISTD junction directly when the station is on hold with the console...
please advise
thanks and regards