Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations dencom on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. quikster2004

    mitel 200icp 4.0.0.17

    I have a mitel 200icp that will not update the time and date correctly. I did get it to take a date and time chage once but 2 days later it reverted back. Any ideas?
  2. quikster2004

    viking announcer on definity

    Is there a way to connect a viking announcer for wakeup calls to a definity? The site does not have an announcement board or speech synthesizer. They really want to use a viking. Is this possible? If so what kind of ports on the pbx are needed?
  3. quikster2004

    lights wont turn off

    I have a definity g3v6 that the lights will light but they will not turn off, I can remove the light by using the clear amw all command, but that is the only way. They have an Innline 2020 vm and the codes are being sent but the switch is not turning them off. Any suggestions?
  4. quikster2004

    audix voice mail

    I have an audix vm where there is one station that the light will not light. I have made sure the phone is set to led on the phone and in the pbx. I have changed ports in the pbx (G3v6), I have rebooted the vm, I have rebooted the pbx. All setting are the same as other stations that are not...
  5. quikster2004

    No board

    I have an avaya G3 V6 with guestworks. I had a TN2464 ds1 board in the pbx and has been there for probably 5 or 6 years to the best of my knowledge. Recently the t-1 kept going down and I noticed when I tested the board or did a list config all it would show no board. I have found the the tn2464...
  6. quikster2004

    analog phones not ringing

    I am using a ger in a hotel environment, my problem is the site complains that some of the analog phones are not ringing, I have replaced the power supply and still no change
  7. quikster2004

    8400B+ data module

    I am having issues getting an 8400B+ data module to work. When connected to the pbx it shows idle. When connected to the pms system the interface never comes up. I have ran looped back through the 9 pin cable out of the back of the data module to the pms system and their port is good. This...
  8. quikster2004

    transferring offsite

    I must be missing something. I am unable to transfer to a number offsite. Trunk to trunk transfer is enabled in the cos. Help!!!!

Part and Inventory Search

Back
Top